Panel Removal - Potterton Promax HE Store 90 Litres Installation & Servicing Instructions Manual

Condensing boilers with integrated hot water storage
Hide thumbs Also See for Promax HE Store 90 Litres:
Table of Contents

Advertisement

Panel Removal

Important: Refer to Page 8 for Storage, Unpacking and Handling Instructions.
Top & Bottom Section
Location Peg
Location Channel
Handholds
(Underneath boiler)
Plumbing Access
Mains power
supply and
Immersion Heater
cable entry holes
Condensate
outlet hole
Lifting and
plumbing
access
each side
© Baxi Heating UK Ltd 2006
Rollers
1
2
4
3
Bottom Section
Union Nuts
(remain with
Bottom Section)
DHW Sensor Pocket
(310mm deep)
General Access
Pull forward Front Panel at the bottom and lift off
Pull up and away Top Panel
Unscrew Upper Panel at the bottom and pull away
Retaining Screws (Upper Panel)
Pull forward Bottom Panel
Top Section
Lift Heat Engine onto
Cylinder. Ensure the
rollers engage into
location channels.
Tilt and slide until front
location pegs drop into
position on the cylinder.
Fig. 1