1. Carefully remove the burner system
(fire box) from the shipping box.
2. Carefully lift the burner system and
place it into the stove body from the
rear of the stove (see figure 13).
3. Slide the burner system to the front of
the stove body (see figures 13 and 14).
4. Place the vent gasket on the outside of
the burner system box over the vent
hole and align the holes(see figure 15).
5. Place the 7" vent collar over the gasket
and align the holes. Secure with hex
head screws provided (see figure 15).
6. Next remove the blower system from
the shipping box .
7. Find the on/off/auto switch and wires
attached to the burner system. You
will need to unplug the wires from the
switch and place the switch in the slot
provided on the side of the blower
system (see figure 16 and figures
43,44 on pages 30,31) .
8. Next push the wires through the 5/8"
round hole located in the bottom of the
blower system and reconnect the wires
to the switch using the labels on the
wires to insure the wires are
reconnected to the correct terminals
(see wiring diagram pages 30,31
figures 43,44)(see figure 16).
9. Secure the blower system to the rear
of the cast stove body with the 4
10mm bolts provided with the stove
(see figure 16).
"CAUTION:
Label all wires
prior to disconnection when
servicing controls. Wiring er-
rors can cause improper and
dangerous operation."
"Verify proper operation after
servicing."
Figure 14– Installing Burner System and Blower System.
Stove Body
Front
Figure 13-Installing Burner System into Cast Stove body.
7" Vent Collar
Figure 15– Installing Vent Collar
On/Off/Auto
Switch
Labeled Wires from Burner System
Go to On/Off/Auto Switch
Figure 16-Secure Blower System
6
Rear
Burner System (Direct
Vent Fire Box)
4 Hex Head Screws
Vent Collar Gasket
Burner System Vent Opening
4 10mm
Bolts
Blower Motor
WARNING: Never touch the blower
wheel while in operation.
On/Off Switch
For Blower
Blower System