13.0 Changing Components – page 37
13.21
Diverter Valve
To change the diverter valve actuator:
1.
Remove electrical plug (Fig. 65).
2.
Depress the locking latch whilst rotating the head
anticlockwise through 45º (Fig. 65) and pull forward
(Fig. 66).
3.
Fit the new diverter valve actuator and reassemble in
reverse order.
To change the diverter valve cartridge:
1.
Remove the diverter valve actuator (Figs 65 & 66).
2.
Using the spanner in the spare cartridge kit, unscrew
the cartridge anti-clockwise and remove it (Fig. 67 &
68) whilst holding the diverter valve body securely with
a suitable tool.
3.
Fit the new diverter valve cartridge and reassemble in
reverse order.