Bosch Gwh 425 Pn - Bosch GWH 715 ES Applications Manual

Tankless and point-of-use water heaters
Hide thumbs Also See for GWH 715 ES:
Table of Contents

Advertisement

Applications manual

2.9 Bosch GWH 425 PN

Features:
Standing pilot ignition
78% thermal effi ciency
Endless hot water for one major application at a time
Modulating gas valve — constant temperature at varying flow rates
Model GWH 425 PN N for natural gas (NG) supply
Model GWH 425 PN L for liquid propane (LP) supply
15-year warranty on heat exchanger
GWH 425 PN Technical Specifi cations
Power input
Minimum fl ow to activate
Flow rates
Thermal Effi ciency
Dimensions
Weight
Modulating gas valve
Ignition
Accessories
GWH 425 PN Installation Specifi cations
Gas connection
Water connections
NG gas pressure
LP gas pressure
Water pressure
Electrical supply
Vertical venting
Horizontal venting
BOSCH THERMOTECHNOLOGY CORPORATION
Natural Gas: 31,000 - 117,000 BTU
LP Gas: 31,000 - 117,000 BTU
0.6 gallons per minute (gpm)
45˚F rise @ 4.2 gpm
55˚F rise @ 3.4 gpm
65˚F rise @ 2.9 gpm
77˚F rise @ 2.4 gpm
90˚F rise @ 2.1 gpm
NG: 78% LP: 78%
25.75" h x 16.75" w x 8.5" d
33 lbs.
yes
Standing pilot
Horizontal vent kit (AQ4) - power
vent kit for horizontal venting
¾" Male NPT
¾" Male NPT
Minimum: 7" W.C.
Maximum: 14" W.C.
Minimum: 11" W.C.
Maximum: 14" W.C.
Minimum: 30 PSI
Maximum: 150 PSI
120VAC - plugs in
5" minimum diameter - natural
draft
AQ4 horizontal vent kit required
for horizontal terminations
GWH 425 PN Installation Clearances
Top (A)
12"
Front (B)
4"
Back
0"
Sides
4"
Floor (C)
12"
LIS TE D G AS VE NT
E S TA B LIS H A O NE
F O O T R IS E B E F O R E
A NY E LB O W S
Fig. 4 Venting confi guration
Installation guidelines:
Venting:
5" minimum diameter — do not reduce vent size.
Refer to installation manual for vent material options
Do not combination vent with any power vented appliances.
Establish a one-foot rise before any elbows
Minimum vent height - 6 feet.
Horizontal sections must slope upwards at least ¼" for every foot
of the horizontal length and be properly supported.
Gas piping:
Heater will not function properly without adequate supply gas
pressure.
Any appliance connector should be ¾" minimum diameter
Plumbing:
Install the included pressure relief valve and pipe to suitable
drain.
Minimum piping diameter is ¾".
Do not solder directly to the bottom of the unit.
Use full port ball valves for isolation valves.
LIS TE D VE NT C AP
MINIMUM 6
FE E T (1.8M)
Applications manual | 11.2007
| 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents