Bosch GWH 715 ES Applications Manual page 23

Tankless and point-of-use water heaters
Hide thumbs Also See for GWH 715 ES:
Table of Contents

Advertisement

Applications manual
3.2.2 Powerstream Pro whole house application with domestic
recirculation loop
The circulator should be controlled by an external aquastat, or with
a timer to run only during times of expected hot water usage.
Ariston Pro GL4Ti
(for pipe runs over
100ft use GL8Ti)
Bronze circulator pump sized
according to UPC standards
(Taco Bronze 007 or Grundfos 15-42B
will cover most homes up to 3 bathrooms)
Potable water
expansion tank
Note: Cold water piping to fixtures not shown for clarity purposes.
Note: This drawing is conceptual in nature and does to address all design, installation or safety considerations.
Additional safety and/or auxiliary equipment may be needed. This diagram is for reference use by officials, designers and licensed installers.
It is expected that installers have adequate knowledge of accepted industry practices for the equipment, procedures, and applications involved.
Drawing is not to scale.
BOSCH THERMOTECHNOLOGY CORPORATION
Symbols
Flow check valve
Service
valves
Powerstream Pro
RP17PT or RP27PT
Hot
Timer or
Flow direction
Aquastat
Sink
Standard tub fixture
Drawing # WH1R
Applications manual | 11.2007
| 23
Cold
CN
rev 06/07