Operation with MIF Command
The FS-1503 can be controlled by MIF commands from Furuno's NBDP, DSC and re-
mote station.
The following explains how MIF command from the DP-6 controls the FS-1503.
Operation on DP-6
1. Press [F4] (window).
2. Select "3: Remote A (TX/RX).
3. Enter a command and a parameter. For example, type FT1234560 and press [Enter] to
set TX freq. to 12345.60 KHz.
4. If the entered command is executed, * appears. If not, ? appears.
NO
Response Signal
⋅ *CR (LF) --- When a command is executed correctly.
⋅ ?CR (LF) --- When a command is incorrect or an error occurs during the
Window
1: Display NMEA Data
2: Calendar
3: Remote A (Tx/Rx)
4: Remote B (DSC)
5: Distress Frequency Tabile
MIF > FT1234560
MIF > *
Radiotelephone
Correct command ?
YES
Executing
Response signal
Output
execution.
Remote
DP-6
Start
Command Output
* received ?
YES
Output next command
2-35
NO