Sharing And Groups; Network Settings; Language And Brilliance Sharing Between Fi-70 Units - Furuno FI-70 User Handbook Manual

Color instrument
Hide thumbs Also See for FI-70:
Table of Contents

Advertisement

Network Settings

Network Settings
Some settings and offsets for the FI-70 may be shared across a CAN bus (NMEA2000) network.
See the list below for details.
1
Select [System] from
the main menu, then
press the function key.
Rudder
º
P
30
System
Ent
[Stand Alone]: Settings are not shared across the network. This unit can be set up individually.
[Slave]: Settings are received from a Multi Function Display (TZTL12F/TZTL15F), or a FI-70 unit assigned as [Master].
[Master]: Settings for this FI-70 are shared across the network. This option is not available if there is a Multi Function
Display (TZTL12F/TZTL15F) in the same network. In this case, the TZTL12F/TZTL15F is made the [Master].
CAN bus (NMEA2000) Network Shared Settings
After setting the sharing levels for the network, settings between units can be shared.
All shared settings are displayed as gray menu items on FI-70 units assigned as [Slave].
The shared settings cannot be adjusted from a [Slave] FI-70 unit.
[Display Format] menu
[HDG/COG Ref], [Mag. Var.], [Time Offset] only
[Data Source] menu
All menu settings, excluding tank information
([Tank1] through [Tank 6]).

Language and Brilliance Sharing Between FI-70 Units

Language and Brilliance Sharing Between FI-70 Units
FI-70 units may be grouped together in one or more groups, allowing language and brilliance settings to be shared
between FI-70 units in the same group.
As shown in the example figure below, adjusting the brilliance settings for one FI-70 unit in Group A changes the brilliance
settings for all FI-70 units in the same group. While one FI-70 unit in a group has the brilliance adjusted or the language
changed, all other FI-70 units in the same group cannot have the brilliance or language settings adjusted.
Enter
Enter
Enter
Enter
Group A
Grouping the FI-70 units eliminates the need to adjust each unit indiviually. Up to three groups (A, B, C) may be set up.
1
Select [System] from
the main menu, then
press the function key.
Rudder
º
P
30
System
Ent

SHARING AND GROUPS

2
Select [Sharing], then
press the function
key.
Key Beep:
Panel Dimmer:
Sharing:
Group
Enter
Enter
Enter
Group B
Select [Group], then
2
press the function
key.
Key Beep:
Panel Dimmer:
Sharing:
Group
System
OFF
8
Slave
A
Ent
[Data Calibration] menu
All menu settings, excluding
[W Angle Response].
[Units] menu
All menu settings.
Enter
Enter
System
OFF
8
Slave
A
Ent
11
3
Select the sharing level
for this FI-70 unit, then
press the function key.
System
Key Beep:
OFF
Stand Alone
Panel Dimmer:
8
Slave
Sharing:
Slave
Master
Group
A
Ent
Enter
E
Enter
Enter
E
Enter
Enter
Group A
Group B
3
Select the group for this
FI-70 unit, then press
the function key.
System
Key Beep:
OFF
A
Panel Dimmer:
8
B
Sharing:
Slave
C
Group
A
Ent
Enter