Ortal Factory Recommended Service - Optal Clear 40 Installation & Operation Manual

40 series; 70 series; 80 series; 110 series; 120 series; 130 series; 150 series; 170 series; 200 series
Table of Contents

Advertisement

Ortal Factory Recommended Service

Service Check list
Model Type: __________________ Serial #: _________ Date: _______
Before, during and after, if there is any doubt, stop and call Ortal USA.
If there is any "No" answer close gas valve and correct.
If you cannot correct, discontinue operation, lockout unit and call Ortal USA.
1.
Outside horizontal/vertical cap. Clean and unobstructed. ( ) Yes ( ) No
2. Check the louver/chase heat release. Clean and unobstructed. ( ) Yes ( ) No
3. Is there an access panel for valve and receiver maintenance? ( ) Yes ( ) No
a. Clean and unobstructed? ( ) Yes ( ) No
b. Allows access to components? ( ) Yes ( ) No
4. LPG Only
a. Is there adequate opening for releasing a potential gas leak at the lowest
point of elevation in the chase? ( ) Yes ( ) No
5. Is glass complete and NOT broken? ( ) Yes ( )No
6. Is area around the fireplace free of wall crack or signs of heat impact? ( ) Yes ( ) No
Make sure the shut off valve is in the on position and there is gas flow. ( ) Yes ( ) No
7. Verify that there is NO gas leak. ( ) Yes ( ) No
8. Turn on the fireplace for visual inspection (30 sec. - 1min)
a. Check if the system has spark. ( ) Yes ( ) No
b. Check if the pilot turns on. ( ) Yes ( ) No
c. Check if the burner turns on. ( ) Yes ( )No
9. Let the glass cool down ( ) Yes ( ) No
10. Remove glass
a. Clean the glass. ( ) Yes ( ) No
b. Remove the media and clean/ vacuum the burner. ( ) Yes ( ) No
c. Return media per installation guidelines. ( ) Yes ( )No
d. Make sure pilot, spark plug and thermocouple area is clear. ( ) Yes ( ) No
11. Check explosion valve
a. Pull explosion valve open. ( )Yes ( ) No
b. Release explosion valve to close. Is the explosion valve closed? ( )Yes ( ) No
c. Is the explosion valve unobstructed? ( ) Yes ( ) No
12. Turn unit on without the glass installed to verify the following.
a. There is spark ( ) Yes ( ) No
b. Pilot turns on ( ) Yes ( ) No
c. Burner turns on ( ) Yes ( )No
d. Measure gas pressure. Inlet _______ W.C., Manifold _______ W.C.
e. Block the flame from the pilot to the thermocouple with a metal or
similar divider and verify that the main burner turns off. ( )Yes ( ) No
13. Reinstall the glass. ( ) Yes ( ) No
14. Check silicon on the glass. If broken, flip glass to the other edge. If the other edge is also
broken, apply new silicon and cure for 24 hrs.
Tell Owner not to turn unit on for 24 hr., until: time _____ date ______ ( ) Yes ( ) No