'ERROR' mode, display the message 'ILLEGAL CODE' and after that will indicate the time. To
avoid the password selection after four running wrong typing the console blocks up next
password entering for 30 sec (for 1 min after 5 typing, for 2 min after 6 typing and etc. After
entering the legal password the blocking will be off.
Getting the partition state
ENTER CODE:
v 1200: DISARMED
Second Flore
The partition has several states due to the states of all zones (alarm loops, addressable
detectors and load circuits) and all devices included. Initially the console displays the state with
the highest priority. The list of priorities in decreasing order can be viewed below in appendix B.
The listed states can concern to zones (e.g., "Intrusion alarm"), devices (e.g., "2-wire line short
circuit") or zones and devices both (e.g., "Power failed").
The console in current version monitors the tampering of the device case and so the
tampering of case makes influence on all states of the partitions to which device's zones belong.
The tampering of detector case on the contrary is not monitored and doesn't affect on the states
of partition.
To get all the states of partition press "TRBL". The console will display the partition
descriptor (name or the number if no named) in the first line and its state of highest priority.
Press " 4 " for scrolling and showing the list of states in decreasing priority order. Press " 3 " to
return the previous entry.
Use " 4 " and " 3 " and press "ENT" to display all zones with such state, for example with
the state "Intrusion alarm". Use " 4 " and " 3 " keys to scroll zone descriptors. The state of zone
is displayed in the upper line but the descriptor of zone is displayed in the lower one (name or
device address with alarm loop number, or addressable detector number, or load circuit number).
Partition arming/disarming
Enter the password with partition controlling rights.
Choose the required partition by means of " 4 " or " 3 " keys or having entered its number.
Press "ARM" for arming or "DISARM" for disarming. Or press "ENT", enter to menu, select the
necessary command and press "ENT".
If partition has armed the console makes sound signal 'Success' and displays new partition state
' v 1200: ARMED'. Otherwise console makes sound signal 'Error' and displays error message:
UNKNOWN PART', 'ACCESS DENIED', 'OPERATION NOT COMPLETED', or another
message diverse from "ARMED".
Message 'UNKNOWN PART' means that partition not exists. Message 'ACCESS DENIED'
means that user has no privileges for controlling this partition by means of this device (see the
section 2.2.2). If the message 'OPERATION NOT COMPLETED' is showed it means that
partition control operation was not completed correctly. It can happen as a result of
disconnection of devices and interface RS-485, or zone absence in the partition or console
database failure.
38
Enter the password with partition controlling rights.
If it is correct the console will display the state of first available
partition. The example demonstrates that the partition named
"Second Flore" has the state "DISARMED". " 4 " and " 3 " keys
are suitable for getting other partition states. Also it is possible
to enter the partition number and press "ENT" key.