Table of Contents

Advertisement

6.5 Main setting mode

To enter the Main setting mode, press
To set or select each setting item, use
Setting item numbers such as [1], [2], etc. are the same as those on the "6.4 Operation flowchart" (p.12).
Character
[1]
SV setting
• Sets SV.
• Setting range: Scaling low limit to Scaling high limit
[2]
SV2 setting
• Sets SV2.
Not available if the Contact input option is not applied, if Serial communication option is
applied, or if OUT/OFF external selection 2 is selected during Contact input function
selection.
• Setting range: Scaling low limit to Scaling high limit
[3]
SV3 setting
• Sets SV3.
Not available if the Contact input option is not applied, if Serial communication option is
applied, or if OUT/OFF external selection 1 or 2 is selected during Contact input
function selection.
• Setting range: Scaling low limit to Scaling high limit
[4]
SV4 setting
• Sets SV4.
Not available if the Contact input option is not applied, if Serial communication option is
applied, or if OUT/OFF external selection 1 or 2 is selected during Contact input
function selection.
• Setting range: Scaling low limit to Scaling high limit
key in the PV/SV display mode.
or
Name, Function, Setting range
key, then register the value with
13
key.
Default value
0
0
0
0