11.7 OUT2 (Heating/Cooling control) action [Reverse (Heating) action] (When setting overlap band)

ON
Control action
OFF
Relay contact
output (OUT1)
Non-contact
voltage output
(OUT1)
DC current
output (OUT1)
Relay contact
output (OUT2)
Non-contact
voltage output
(OUT2)
Indicator
(OUT1)
Lit
Indicator
(OUT2)
Unlit

11.8 OUT2 (Heating/Cooling control) action [Direct (Cooling) action]

ON
Control action
OFF
Relay contact
output (OUT1)
Non-contact
voltage output
(OUT1)
DC current
output (OUT1)
5
Relay contact
output (OUT2)
6
Cycle action is performed according to deviation.
5
+
Non-contact
voltage output
6
-
(OUT2)
Cycle action is performed according to deviation.
Indicator
(OUT1)
Unlit
Indicator
(OUT2)
Lit
Heating P-band
Cooling P-band
Overlap
band
Heating
action
SV setting
7
7
7
8
8
8
Cycle action is performed according to deviation.
7
7
7
12V DC
12/0V DC
8
8
8
Cycle action is performed according to deviation.
7
7
7
20mA DC
20 to 4mA DC
4mA DC
8
8
8
Changes continuously according to deviation.
5
5
6
6
Cycle action is performed according to deviation.
5
5
0V DC
12/0V DC
6
6
Cycle action is performed according to deviation.
Cooling P-band
Heating P-band
(Cooling
action)
SV setting
7
8
Cycle action is performed according to deviation.
7
+
+
0V DC
8
-
-
Cycle action is performed according to deviation.
7
+
+
4mA DC
4 to 20mA DC
8
-
-
Changes continuously according to deviation.
5
6
5
+
+
12V DC
12/0V DC
6
-
-
Heating/Cooling control can be used
by adding Heating/Cooling control
ON
option.
(Cooling
action)
Heating proportional band can be set
OFF
during [6] OUT1 proportional band setting,
and cooling proportional band can be set
during [7] OUT2 proportional band setting
in the Sub setting mode. (p.14)
Overlap band can be set during
0V DC
[36] Overlap band/Dead band setting
in the Setup mode.(p.19)
[48] Direct/Reverse control can be set
in the Setup mode. (p.21)
5
6
5
12V DC
6
Unlit
Lit
ON
Heating
action
OFF
7
7
8
8
7
7
+
0/12V DC
12V DC
8
8
-
7
7
+
20mA DC
8
8
-
5
6
5
0V DC
6
Lit
Unlit
32
: Acts ON (lit) or OFF (unlit).
: Represents Heating control
action.
: Represents Cooling control
action.
Heating/Cooling control can be used
by adding Heating/Cooling control
option.
Heating proportional band can be set
during [6] OUT1 proportional band
setting, and cooling proportional band
can be set during [7] OUT2 proportional
band setting in the Sub setting mode.
(p.14)
[48] Direct/Reverse control can be set
in the Setup mode. (p.21)
: Acts ON (lit) or OFF (unlit).
: Represents Heating control
action.
: Represents Cooling control
action.