PV color selection
• Selects PV display color. (Refer to Section "8.4 Changing PV color" on p.26.)
[55]
PV color range setting
• When
continuously, and at the same time Alarm 1 or Alarm 2 is ON; Red) is selected during PV
color selection, the value of green PV color range can be set.
• Setting range: 0.1 to 100.0 ( ) DC voltage, current input: 1 to 1000 (The placement of
[56]
Backlight time setting
• Sets time to backlight from no operation status until backlight is switched off.
When set to 0, the backlight remains ON.
Backlight relights by pressing any key while backlight is OFF.
• Setting range: 0 to 99 minutes
[Alarm Energized/Deenergized]
When [Alarm Energized] is selected, the alarm output (between terminals 3–4, or 5–6) is conductive (ON) while
EVT1 (or EVT2) indicator is lit. The alarm output is not conductive (OFF) while EVT1 (or EVT2) indicator is not lit.
When [Alarm Deenergized] is selected, the alarm output (between terminals 3–4, or 5–6) is not conductive (OFF)
while EVT1 (or EVT2) indicator is lit. The alarm output is conductive (ON) while EVT1 (or EVT2) indicator is not lit.
[This function is not available for the Heater burnout alarm (optional).]
High limit alarm (when Energized is set)
ON
OFF
SV setting
(Fig. 6.8-2)
[Contact input function] Actions depend on OUT/OFF key function selection.
When OUT/OFF function ([52]
Connecting terminal number
Between 17-18
Between 16-18
(DI1-COM)
(DI2-COM)
Open
Closed
Open
Closed
When Auto/Manual control function ([52]
Connecting terminal number
Between 17-18
Between 16-18
(DI1-COM)
(DI2-COM)
Open
Closed
Open
Closed
Name, Function, Setting range
: Green
: Red
: Orange
: When Alarm 1 or Alarm 2 is ON, PV color turns from green to red.
: When Alarm 1 or Alarm 2 is ON, PV color turns from orange to red.
: PV color changes continuously (Orange
: PV color changes continuously (Orange
Alarm 1 or Alarm 2 is ON (Red).
(PV color changes continuously) or
A1 hysteresis
+ A1 set point
in the Setup mode) is selected
Set value memory external
selection (
Open
Open
Closed
Closed
Set value memory external
selection (
Open
Open
Closed
Closed
the decimal point follows the selection.)
High limit alarm (when Deenergized is set)
A1 hysteresis
ON
OFF
+ A1 set point
SV setting
(Fig. 6.8-3)
Contact input function: [50] in the Setup mode
OUT/OFF external
)
selection 1 (
SV
SV2
SV3
Control output OFF
SV4
in the Setup mode) is selected
Contact input function: [50] in the Setup mode
OUT/OFF external
)
selection 1 (
SV
SV (Automatic control)
SV2
SV2 (Automatic control)
SV3
Manual control
SV4
22
Default value
Green
Green
Red).
Green
Red), and at the same time
5.0
(PV color changes
0 minutes
"A1" means Alarm 1.
OUT/OFF external
)
selection 2 (
SV
SV2
Control output OFF
OUT/OFF external
)
selection 2 (
(Automatic control)
Manual control
)
SV
)
SV