Download Print this page
Hide thumbs Also See for TG100:

Advertisement

Quick Links

How to Use
1. Push the On/Off button by the display window. The display will
read
TG100\TG120
2. Releasing the on/off button, last measured temperature will be
Model:
shown for about 2 seconds. Then shows the self-test temperature
37.0°C(98.6°F),and then Lo°C (Lo°F) displays.
EN
3. Wipe or dip the probe with alcohol for disinfection. Position the
probe in oral, rectal or axillary site.
4. Once the degree sign °C ( °F) on the display has stopped flash-
ing (usually within 30 to 60 seconds), an Beep signal will sound
Instruction
Manual
for approx. 10 times, the measured temperature is shown on
LCD window. The temperature reading will not change after
the unit is removed from testing position. If the temperature
www.rossmax.com
<37.8°C(100.0°F ), the buzzer will alarm "Bi---Bi---Bi---Bi---". If
the temperature ≥ 37.8°C (100.0°F), the buzzer whose frequency
is higher will alarm "Bi-Bi-Bi----Bi-Bi-Bi--" about 10 times rather
Introduction
than"Bi---Bi---Bi---Bi---"
5. The unit will automatically turn off in 10 minutes for energy saving.
The Digital Medical Thermometer provides quick, highly accurate
However, to prolong the life of the battery, it is suggested to press
reading over the human body temperature range. Please read the
the On/Off button to turn the unit off once the measurement
instructions completely first.
is done.
The quality of the thermometer has been verified and conforms to
6. Please dispose of any used battery and the thermometer accord-
the provisions of the EC council directive 93/42/EEC(Medical Device
ing to the local regulations.
Directive) Annex I essential requirements and applied harmonized
standards. EN 12470-3: 2000 /A1: 2009 Clinical thermometers-Part
3: Performance of compact electrical thermometers (non-predictive
and predictive) with maximum device.
Attention: Consult the accompanying documents. Please read
this manual carefully before use. Please be sure to
keep this manual.
Oral Use
Place the probe well under the patient's tongue. Confirm the patient
to keep his mouth closing for about 1 minute.
Display
Do not drink hot or cold fluids, exercise, and smoke or per-
Probe
form other activities prior to a reading. These activities will
Battery
raise or lower temperature readings when compared to your
normal, average temperature.
Cover
Axillary Use
ON/OFF Button
Tightly place probe in the patient's armpit for about 1~5 minutes.
* Please ensure the close contact between the probe and the armpit
of the baby or children.
for 2 seconds and beep sound will be heard.
Rectal Use
Always uses probe cover when taking rectal measurements.
1. Commonly used for young children when it is difficult to take an
oral or axillary temperature.
2. Lubricate with a water-soluble gel. Do not use petroleum jelly.
3. Gently insert the probe tip no more than 1.5-2 cm into the rectum
for about 1 minute. Do not force the tip into the rectum if resist-
ance is encountered.
4. Disinfect the thermometer after use. Refer to "cleaning and
disinfection"section.
ºC /ºF Switchable
Temperature readings are available in the Fahrenheit or Celsius scale
(°C / °F; located in the right of LCD.) With the unit off, press and
hold the On/Off Button for approximately 4 seconds to change the
current setting.
Battery Replacement
1. When the
the battery is exhausted and needs replacement.
Note: After step 2, if the room temperature is greater than
2. Pull the battery cover off in the direction shown below.
32.0°C (89.6°F ). it will be displayed the room tempera-
3. Pull out the battery with a sharp objects such as pen. Keep ex-
ture.
hausted battery from reach-
Note: Usage of the probe cover may result in a 0.1°C(0.2°F)
ing by the children.
difference from actual temperature.
Note: To clean the probe before and after using the ther-
4. Place a new 1.5V D.C. but-
mometer to ensure an accurate reading and avoid cross
ton size battery type SR41
contamination approximately.
or LR41 or equivalent in the
chamber with positive side
faced up and negative side
faced down.
5. Install the battery cover back.
Display on the LCD
M: Last measured temperature.
Troubleshooting
Error message
Problem
The system is
not functioning
properly
Temperature
taken is higher than
42.9°C (109.2°F)
(bi-bi...bi)x10
Temperature taken
is lower than 32°C
(89.6°F)
Dead battery:
Battery icon is
flashing, can't be
measurable.
Cleaning and Disinfection
1. Clean the unit by wiping it with a dry cloth and sterilize the probe
with ethyl alcohol.
2. Don't let the unit contact any chemical thinner.
appears on the upper right corner of the LCD,
3. Not waterproof. Do not soak the display in water. Only the probe
is waterproof.
Caution
• Do not bend or drop the thermometer. It is not shockproof.
• Do not boil probe for disinfect.
• Do not store the unit under direct sunlight, at a high
temperature, in high humidity or dust. Neither store the
unit under the sunlight, nor at the high temperature or
humidity.
• Do not disassemble. See BATTERY REPLACEMENT to replace battery.
• Avoid strong electromagnetic interference such as microwave ovens
and cell phones.
• Please be noticed to keep the probe dry before putting the
thermometer into the carry case.
• The thermometer contains small parts (battery, etc.) that can be
swallowed by children. Therefore never leave the thermometer
: When the
appears on the upper
unattended to children.
right corner of the LCD, the battery is
• The thermometer should be cleaned after measurement no matter
exhausted and needs replacement.
the probe cover has been installed or not.
• Battery should not be charged or placed into extreme heat as it
may explode.
• Do not use the thermometer in ear. Intended use is for oral, axillary
Solution
and rectal measurement.
Unload the battery, wait for 1
• Use of the probe cover may result in a 0.1ºC(0.2ºF) discrepancy from
mins and repower it.
actual temperature.
If the message reappears, con-
• Remove battery from the thermometer when not in operation for
tact the retailer for service.
a long time.
Take a new temperature meas-
• If the unit is stored in an extreme environment before measurement,
urement after 6 sec.
please make sure it has been firstly adapted in the room
temperature, so that the unit can be measured normally.
Take a new temperature meas-
• Please note that this is a home healthcare product only, and it is not
urement after 6 sec.
intended to serve as a substitute for the advice of a physician or
medical professional.
Suggest to replace the battery.
• Do not use this device for diagnosis or treatment of any health
problem on disease. Measurement results are for reference only.
Contact your physician if you have or suspect any medical problems.
Do not change your medications without the advice of your
physician or healthcare professional.
• This device may not meet its performance specification if stored
or used outside temperature and humidity ranges specified in
specifications.
• If this device is used according to the operations instruction, periodic
re-calibration is not required. If you still have questions, please send
the device to dealers.
• Please do not dispose of the product in the household waste at the
end of its useful life. Disposal can take place at your local retailer or
at appropriate collection points provided in your country.
• This device is for oral, axillary and rectal use only.
• High, prolonged fever requires medical attention especially for
young children. Please contact your physician.
• For save reason, during children's temperature measurement, please
keep them from crying, walking, talking and any related dangerous
activities.

Advertisement

loading
Need help?

Need help?

Do you have a question about the TG100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rossmax TG100

  • Page 1 Solution read for 2 seconds and beep sound will be heard. and rectal measurement. Rectal Use TG100\TG120 2. Releasing the on/off button, last measured temperature will be The system is Unload the battery, wait for 1 Model: • Use of the probe cover may result in a 0.1ºC(0.2ºF) discrepancy from not functioning mins and repower it.
  • Page 2 ±0.2°C under 35.5°C or over 42.0°C determined by an electromagnetic site survey. The customer or the user of the TG100/TG120 should assure that it is used in such an environment. instruction manual. Please contact rossmax service. (±0.4°F under 95.9°F or over 107.6°F) a.

This manual is also suitable for:

Tg120