Horizontal Terminations; Flex Vent 4" X 6-7/8" (102Mm X 175Mm) - Regency GF900C-NG1 Owner's Manual

Hide thumbs Also See for GF900C-NG1:
Table of Contents

Advertisement

These venting systems, in combination with the GF900 Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination
Locations" section.
Regency
Direct Vent (Flex) System Termination Kits includes all the parts needed to install the GF900 using a flexible vent.
®
FPI Kit #
Length
Contains:
#946-515
1.2 m
1)
2)
3)
4)
5)
#946-516
3 m
6)
7)
8)
9)
Notes:
1) Liner sections should be continuous without any
joints or seams.
2) Only Flex pipe purchased from Regency
used for Flex installations
3) Horizontal vent must be supported every 0.9m.
4) Regency
®
Direct Vent System (Flex) is only approved
for horizontal terminations.
5) Flex system can only be used up to a maximum
continuous vent length of up to 3m. If longer runs
are required, rigid pipe must be used.
Regency GF900C Gas Fireplace

HORIZONTAL TERMINATIONS

FLEX VENT 4" X 6-7/8
6-7/8" flexible outer liner (Kit length)
4" flexible inner liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
may be
®
" (
102MM X 175MM)
(102mm)
INSTALLATION
Vent Guard - if required*
(Part #946-506/P)
19