Gabarron RF3P Installation Instructions And User Manual page 6

Intertia electric radiator
Table of Contents

Advertisement

It increases the
values.
SUN indicator
Press once to see the SUN
temperature value.
Press + or – keys to modify
the value.
MOON key:
Press once to see the
MOON temperature value.
Press + or – keys to modify
the value.
MOON indicator
It decreases the
values.
Digital models have built in an electronic thermostat with a sensibility of 0.1 ºC. It is possible to set temperatures with an accuracy of 0.5ºC.
The daily or weekly programmer (selectable) allows you to allocate three different temperature levels to any of the 48 intervals of 30 minutes of the
day.
SWITCHING ON THE HEATER AND SETTING THE TIME
Turn the mode selector dial to P position and press the
+
-
minutes by pressing
and
is necessary to set the time press the
FROST PROTECTION MODE
With this mode on, if the room temperature drops below 3ºC the heater will connect itself automatically.
If the display shows the time the heater is in frost protection mode. Press the
display) to standard mode (temperature is shown in the display) and vice versa.
SELECTOR "O" , "P", "I".
Position "0" : The heater is switched off permanently. The display is switched off.
Position "P" : The heater is following a program. It will maintain the SUN, MOON or
position if the display shows the time the heater is frost protection mode.
Position "I" :
The heater is maintaining the SUN temperature constantly both luminous indicators SUN and MOON will be lit. This could be useful
when SUN temperature is required and we do not want to modify the program. At this position if the display shows the time the
heater is in frost protection mode. Press the
mode (temperature is shown in the display) and vice versa.
Inertia Electric Radiators
DIGITALS MODELS RFE
Key + :
SUN key:
Key:
key more than two seconds. The display will show the time intermittently. Set the
keys and press the
. Set the hours the same way. Press once more the
key and repeat the above steps.
T
:
T
key to shift from frost protection mode (time is shown in the
T
T
key to shift from frost protection mode (time is shown in the display) to standard
6
Digital DISPLAY:
It
shows
temperature
messages.
Heating indicator:
This small dot will be lit when
the
heater
energy.
Frost protection key:
If the display shows the time
the heater is in frost protection
mode. Press this key to shift
from frost protection mode to
standard mode and vice versa.
Press this key for more than
two seconds to set the time or
day of the week.
PRG key:
Allows you to create check
or modify programs.
Move forward with + or –
keys and allocate the SUN,
MOON, or T temperature to
any of the 48 intervals of 30
minutes of the day by means
of the relevant key.
Selector:
0
The heater is switched off
permanently.
P
The heater is following a
program.
I
The heater is maintaining
the
SUN
constantly. Both indicators
will be lit at the same time.
key to store the time. If at any time it
temperatures as per the introduced program. At this
the
time,
and
other
is
consuming
temperature

Hide quick links:

Advertisement

Table of Contents
loading