MIXING MPLIFIER
5. OE Stream Setting OE Stream
OE-212N is Network
broadcasting system over the internet network which makes a possible to build a broadcasting system
without a distance limitation.
PMU-N series can broadcast audio streaming from OE-212N over the network.
Select the identical operation mode of connected OE-212N and configure the server IP address and port.
Mode: It must be selected as same mode of OE-212N (stream server) for normal operation.
IP ddress: Set the IP address of OE-212N which is communicated with PMU-N.
Port: Use the same port of OE-212N
Buffer rate: The initial value is set as 3%. Lower value can reduce a buffering time and higher value can
increase the buffering time but stability to play
※Caution : If
OE-212N is set with DHCP, the IP addess may be changed when
after power was turned off. When PMU-N is not connected with
check the correct IP address of OE-212N.
18
PMU-360N/480N/600N
udio Stream Server/Client equipment developed by Inter-M. It can be built a
OE-212N is turned on
OE-212N, make sure to