Installation; Fixing The Hood To The Lower Part Of The Wall Cabinet; Extraction Through An Outside Wall; Recirculation - Beko CTB 6254 X User Manual

Cooker hood
Table of Contents

Advertisement

3
Installing your appliance
In the case of assembly of the appliance in the
suction version prepare the hole for evacuation
of the air.
We recommend the use of an air exhaust tube
which has the same diameter as the air exhaust
outlet hole. If a pipe with a smaller diameter
is used, the efficiency of the product may be
reduced and its operation may become noisier.
If your appliance has been designed for use in
habitations supplied with acentralised suction
device perform the following operations:
The switch controls opening and closure of a
valve using a thermoelectical device. By placing
the switch in the ON position, after a minute,
the valve opens rotating 90° allowing suction
of the stale air. By placing the switch in the OFF
position, the valve closes after 100 seconds.

3.2 Installation

The following instruction should be followed to
carry out the correct installation of the cooker
hood.
1. Mounting of the cooker hood on the lower side
of the cupboard.
2. Selection of the version (extraction Fig.3A or
filtration Fig.3B).
3.3 Fixing the hood to the lower part
of the wall cabinet
This type of appliance must be fitted inside a cab-
inet or inside another type of support structure. To
fix it in place, use 4 screws which are suitable for
the type of cabinet, making holes in accordance
with the diagram shown in (Fig.1). To fit the appli-
ance correctly, align the front panel of the cooker
hood with the cabinet door and adjust spacer L
using screws P (Fig.2), then ensure the appliance
meets the cabinet at the rear.
10 / 14 EN
3.4 Extraction through an outside
wall
The appliance expels the fumes through an
outside wall or a duct. It is necessary to buy a
telescopic pipe in accordance with the standards
in use (inflammable) and connect it to flange H
(Fig.3A).

3.5 Recirculation

To transform the cooker hood from the extraction
version to the re circulating one fit the supplied
activated carbon filter. The filter must be fitted to
the extracting group cooker hood in the centre of
the fan grille by twisting it by 90 degrees until it
is gripped securely (Fig.5). For this operation re-
move the anti-grease filter(s) G (Fig.4). The clean
air is returned into the room through a connecting
tube passing inside the cupboard and connected
to the ring H (Fig.3B).