Product Framework And Internal Components; Hydraulic Circuit - Heating - Ferroli Domina F 24-30 E Technical Manual

Wall-mounting gas boiler
Table of Contents

Advertisement

2. PRODUCT FRAMEWORK AND INTERNAL
COMPONENTS
2.1 Hydraulic circuit – heating
Hydraulic diagram for heating
When there is a call for heat, the room thermostat or control system make the burners ignite and the
circulation pump come into operation. The heat contained in the products of combustion is transferred
to the water by the system via the exchanger. For more details on the operating logic, refer to chap.3.
29-187
16
5
49
27
82
20
42
34
114
14
74
10
8
Version - 09.2002
Supplied By www.heating spares.co Tel. 0161 620 6677
DOMINA F 24 - 30 E
FERELLA F 24 - 30 MEL
MILOS AIR COMPACT E
-
+
7
9
11
Key
43
5
Airtight chamber
7
Gas inlet
8
Tap water outlet
9
Tap water inlet
50
10
System delivery
11
System return
14
Safety valve
16
Fan
20
Burner unit
27
Heat exchanger
56
29
Fume outlet collar
32
Heating circulator
34
Heating temperature sensor
42
Tap water temperature
81
sensor
43
Air pressure switch
44
Gas valve
49
Safety thermostat
50
Heating thermostat
56
Expansion tank
74
Heating system cock
81
Ignition electrode
44
82
Detection electrode
114
Water pressure switch
136
Flow meter
187
Fume diaphragm
32
136
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ferella f 24-30 melMilos air compact e

Table of Contents