Lexmark X543 Service Manual page 65

Hide thumbs Also See for X543:
Table of Contents

Advertisement

Service error messages (1XX, 8XX and 9xx) (continued)
Error code
Description
Front calibration strip has excessive
846.06
dark area
Front magnification exceeds limits
846.07
Modem Failure
847
Fax Storage
847.01
Fax Storage
847.02
Modem/Config ID Mismatch
848
Modem/Config ID Mismatch
848.01
HD/Config ID Mismatch
849
HD/Config ID Mismatch
849.01
9xx service errors
900.xx Service
Unrecoverable RIP software error/
RIP Software
illegal trap.
902.xx Service
A general engine software error.
Engine Software
903.xx Service
A general engine software error.
Engine Software
904.xx Service
A general engine software error.
Engine Software
905.xx Service
A general engine software error.
Engine Software
906.xx Service
A general engine software error.
Engine Software
Action
Front excessive variability for Mono, Red,
Green, or Blue. Go to
"CCD service
check" on page 2-68
Rear excessive variability for Mono, Red,
Green, or Blue. Go to
"CCD service
check" on page 2-68
The Configuration ID bit that describes the
device's modem doesn't match the actual
modem installed in the device.
The amount of flash storage available on
the device is too small. Note: The NAND
Flash partition can shrink as bit failures
cause blocks to be invalidated. Go to
"Format Fax Storage" on page
the issue is not fixed, replace the controller
board. Go to
"Controller board removal"
on page
4-18.
The devices' flash partition is invalid or
unavailable. Go to
"Format Fax Storage"
3-34. If the issue is not fixed,
on page
replace the controller board. Go to
"Controller board removal" on
page
4-18.
A device doesn't have a modem installed,
even though its Configuration ID indicates
that a modem should be present.
A device has a modem installed, but its
Configuration ID indicates that a modem
shouldn't be present.
A device doesn't have a hard drive
installed, even though its Configuration ID
indicates that a hard drive should be
present.
A device has a hard drive installed, but its
Configuration ID indicates that a hard drive
shouldn't be present.
Go to
"900.xx—System software error"
on page
2-31.
Go to
"90x.xx error (902.xx–907.xx)" on
page 2-33
Go to
"90x.xx error (902.xx–907.xx)" on
page 2-33
Go to
"90x.xx error (902.xx–907.xx)" on
page 2-33
Go to
"90x.xx error (902.xx–907.xx)" on
page 2-33
Go to
"90x.xx error (902.xx–907.xx)" on
page 2-33
Diagnostic information
7525-xxx
Previous
Next
Go Back
3-34. If
2-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

X546X544

Table of Contents