Reset Fuser Count

Resets the fuser count value to zero. The Event Log records each time that a user executes the Reset Fuser
Count operation. See
Maintenance Warning and Intervention function is enabled in the printer Configuration ID.
To reset the fuser count:
Select Printer Setup from Diag Menu, and press Select (
1.
2.
Select Reset Fuser Cnt, and press Select (
Select Reset, and press Select (
3.
Resetting Fuser Count Value appears.
To cancel a reset, press Back (

EP Setup

EP Defaults

This setting is used to restore each printer setting listed in EP SETUP to its factory default value. To restore EP
Defaults:
1.
Select EP Setup from Diag Menu, and press Select (
Select EP Defaults, and press Select (
2.
3.
Select Restore to reset the values to the factory settings, and select Do Not Restore to exit without
changing the settings.
To cancel and return to the menus, press Back (

Fuser Temp

This adjustment can be used to help solve some customer problems with paper curl on low-grade papers and
problems with letterheads on some types of media.
The fuser temperature can be adjusted to: Low, Normal, High. The default is Normal.
To restore EP Defaults:
Select EP Setup from Diag Menu, and press Select (
1.
Select Fuser Temp, and press Select (
2.
Select Normal, High, or Low. The default is Normal.
3.

DC Charge Adjust, Deve Bias Adj, Transfer Adj

Each of these three settings enables you to adjust the high-voltage levels controlling the electro photographic
process. You will use these settings to compensate for unusual operating circumstances such as high humidity.
The printer uses the value of these settings together with other settings to calculate printing speed and media
selection.
"Event Log" on page 3-32
).
).
).
).
for more information. This setting appears only if the
).
).
).
).
).
7525-xxx