Troubleshooting

If you are experiencing communication problems with the AXB-EM232, check the
communications settings for the device. The RS-232 communication parameters for this device are
set via the eight-position RS-232 DIP switch. On the AXB-EM232, the RS-232 DIP switch is
located on the front panel. Verify that this DIP switch is set to the default positions indicated in
below.

Setting the RS-232 DIP switch (S2)

The following describes the RS-232 DIP switch default positions:
The following table lists the RS-232 DIP switch settings:
RS-232 DIP Switch (S2) Settings
Position
Function Stop Bits Data Bits
PT10-ADD Additional Camera Pan/Tilt System
• 9,600 baud
• No parity
• 8 bits
• 1 stop bit
1
2
3
Parity
Off
Off
Off
Off
2 bits
7 bits
Unused
On
On
On
Off
1 bit
8 bits
Unused
Off
On
Unused
On
On
Unused
Off
Off
Unused
On
Off
Even
Off
On
Odd
On
On
None
4
5
6
7
Baud Rate
Off
Off
Off
300
Off
On
Off
600
Off
Off
On
1,200
Off
On
On
2,400
On
Off
Off
4,800
On
On
Off
9,600
On
Off
On
19,200
On
On
On
38,400