STEP 4
INSTALL THE BOILING TANK
• The boiling tank must be installed below the dual faucet
• The boiling tank must be mounted vertically.
• T he boiler tank is designed to sit on the sink cabinet
floor. However there are "keyhole" cut-outs provided
in the back of the unit to allow for wall mounting if
required.
• T he boiler tank must be located within 600mm of the
dual faucet.
STEP 5
FAUCET / BOILING TANK CONNECTION
WATER SUPPLY TO BOILER – (white tube)
• The end of the white tube must be cut clean and square.
• R emove red locking clips from the white push-lock fitting
before connecting to the boiling unit and tube.
• F irmly connect white push lock fitting to boiling unit, pull
back to ensure it is locked and refit red locking clip.
• F irmly insert the white tube into the push-lock fitting,
pull back to ensure it is locked into position, and refit the
locking clip.
STEP 6
HOT WATER FROM BOILER (CLEAR SILICONE TUBE)
• C onnect the clear silicon tube to the central outlet
located in the top of the boiling tank.
• S ecure the large silicon tube with the hose
clamp supplied.
Adesso, Futura
DANGER
WARNING
• Be sure the hoses are not kinked
IMPORTANT
or twisted.
• Tubes must be cut to a convenient
length to avoid sagging but must
not be stretched taut.
Dual Faucet
To Filter/Cold
Water supply
Water to
boiling tank
(white tube)
Water to
boiling tank
(white tube)
Maximum distance
between faucet
and boiling tank
= 600mm
Boiling Tank
Hot water
to dual faucet
(clear tube)
Boiling Tank
Hot water
to dual faucet
(clear tube)
Boiler
Hose
Clamp
Boiling Tank