Summary of Contents for Water Filters Australia K-WFADUOGN

  • Page 1 Water Filters Aust Owners Manual INSTANT HOT + AMBIENT FILTERED DISPENSING UNIT MODEL: K-WFADUOGN WFA recommends that a qualified tradesperson installs your WFA DUO system.
  • Page 2: Component Checklist

    COMPONENT CHECKLIST MAIN COMPONENTS Boiling Tank Dual Faucet Push Lock Fitting Locking Clips x 2 (with safety lock) DISPENSER FITTING KIT Rubber Washer Metal Washer Locking Nut Boiler Hose Clamp Chrome Base Plate with O-Ring Threaded Locking Bolt INSTALLATION KIT ¼"...
  • Page 3: Electric Shock Hazard

    IMPORTANT INFORMATION Adesso, Futura PLEASE READ ALL INSTRUCTIONS CAREFULLY DANGER SAFETY WARNING • F or continued safety of the WFA Duo, the unit must be installed, operated & maintained in IMPORTANT accordance with the manufacturer's instructions. • The WFA Duo must be installed in accordance with AS/NZS 3500.4. Adesso, Futura ELECTRIC SHOCK HAZARD DANGER • To prevent electric shock, do not place cord, plugs or appliance in water or other liquid. WARNING • Do not operate any appliance with a damaged cord, plug, or after the appliance malfunctions. IMPORTANT • I f the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Page 4: Typical Installation

    INSTALLATION PRE-REQUIREMENTS POWER SUPPLY • A standard 10amp 3pin power outlet conveniently placed within 1m of the intended location of the boiler tank. This must be installed by a qualified electrician. WATER SUPPLY • A standard cold water supply fitted with a 15mm stop tap situated within easy access of the intended location of the boiler tank. This must be installed by a qualified plumber and in accordance with local &...
  • Page 5: Installation

    INSTALLATION STEP 1 Mixer Tap DRILL 35MM HOLE FOR DUAL FAUCET • Y ou will need to drill a 35mm diameter hole in the bench top or sink where you would like to place the dual faucet. • T he dual faucet must be within 600mm of the proposed location of the WFA Duo under bench boiling tank, and filter system (if included).
  • Page 6 STEP 4 Dual Faucet INSTALL THE BOILING TANK Maximum distance • The boiling tank must be installed below the dual faucet between faucet and boiling tank • The boiling tank must be mounted vertically. = 600mm • T he boiler tank is designed to sit on the sink cabinet To Filter/Cold Water supply floor. However there are “keyhole” cut-outs provided in the back of the unit to allow for wall mounting if required.
  • Page 7 STEP 7 CONNECT TO WATER SUPPLY The Installation Diagram shows an overview of the water supply connection including the Pressure Limiting Valve. Pressure Limiting • T he 350kPa pressure Dual Check limiting dual check Valve 350kPa Locking clip valve (PLVDC) must be connected to the stop tap as shown. Use plumbing tape to create seal.
  • Page 8: Commissioning And Testing

    STEP 10 COMMISSIONING AND TESTING Adesso, Futura • O pen cold tap on dual faucet DANGER WARNING DO NOT CONNECT TO POWER SUPPLY AT THIS TIME IMPORTANT STEP 11 • T urn on water supply Stop tap (not supplied) STEP 12 • A llow water to flow consistently and evenly from the dual faucet for 1–2 minutes before turning off the cold water tap. • C heck all fittings and tube connections for water leakage.
  • Page 9: Check For Leaks

    STEP 14 CHECK FOR LEAKS • C heck all fittings and tube connections to and from the boiling tank for water leakage. • I f any leaks are noted ensure they are repaired before moving onto the next step. STEP 15 Power supply CONNECT TO POWER SUPPLY • P lug power lead into power supply and switch on Pressure Limiting Valve ”...
  • Page 10 STEP 17 • O nce the boiler has reached boiling point steam and hot water will begin venting out Press down of the dual faucet. and forward Adesso, Futura DANGER SCALDING DANGER WARNING IMPORTANT STEP 18 • S lowly turn the thermostat dial anti clock-wise until the status light changes to green. This indicates that the boiler has stopped heating and the hot water has reached the set temperature.
  • Page 11: Troubleshooting

    TROUBLESHOOTING WATER IS NOT HOT (assuming cold water supply is connected properly and valve is open) • C heck that the power supply is live. • C heck if the boiling tank is plugged into the power supply and turned on. • T urn thermostat control dial fully clockwise. This may produce boiling water in approximately 15 minutes and possibly be accompanied by a gurgling sound in the tank and/or water "sputtering" from the dual faucet. • T he self re-setting thermal fuse may have tripped. Turn thermostat dial to the “MIN” position, unplug boiling tank from power supply and allow 1/2 hour to cool before repeating procedures outlined in Steps 15 onwards. HOT WATER IS SPURTING OUT OF THE DUAL FAUCET. • C heck all tube connections are correct.
  • Page 12: Filter System

    FILTER SYSTEM WFA Premium Water Filter System Model No: WFA12 IMPORTANT NOTICE: • R eplace cartridges when capacity is reached, or when flow becomes too slow, but at least Read this performance data sheet and compare annually. the capabilities of this unit with your actual water treatment needs. SPECIAL NOTICES: FEATURES: • T his drinking water system must be maintained according to manufacturer’s instructions, • F inely polishes treated water to premium including replacement of filter cartridges.
  • Page 13: Performance Data Sheet

    PERFORMANCE DATA SHEET Max. Permissible Influent Challenge Product Water Reduction Minimum Average Substance Concentration Concentration Requirements Reduction Requirements Standard 42 Aesthetic Effects Chlorine 2.0mg/L±10% 5ppm ≥50% Particulate at least 10,000 99.8% ≥85% Class 1 particles particles/mL 0.5 to<1um Standard 53 Health Effects Cyst Minimum 50,000/L 99.95% 99.99% 99.99%...
  • Page 14: What This Warranty Does Not Cover

    (with a temperature with WFA’s printed instructions and has range between 2 and 38°C). not been installed in compliance with all applicable laws, regulations and industry Water Filters Australia Pty Ltd (WFA) warrants standards; to you, the first person who has purchased and used the unit (“you”) that this unit is free from • T he unit has not been used in accordance with defects due to faulty material and workmanship the manufacturer’s instructions;...
  • Page 15 WARRANTY CONTINUED WARNING Limitation of Liability of WFA under this warranty: Where a warranty exists or is implied WFA does not recommend making alterations by law, WFA’s liability is limited (to the extent to your existing plumbing to accommodate this that it can be limited) to repair or replacement system. If you wish to modify existing plumbing of the faulty Replaceable Element or the unit or you must comply with AS 3500 and use a licensed...
  • Page 16 Distributed by Water Filters Australia Pty Limited ABN: 78 089 574 489 Unit 1, 91-93 Old Pittwater Road, Brookvale NSW 2100 PO Box 636 Freshwater NSW 2096 Phone: 61 2 9905 6211 Fax: 61 2 9905 6255 Email: info@wfa.com.au Web: www.wfa.com.au...