Technical specifications

Unit
Function
YP3040
Input voltage
Power consumption
Movement range
Movement speed
Protocol (default)
Bit rate (default)
Address (default)
Operating temperature
Load
Weight
Protection class
Construction

Troubleshooting

Problem
YP3040 does not move
YP3040 moves when power is
applied, but is otherwise
unresponsive to commands
Pan
Tilt
Pan
Tilt
Torque (brace axis, see page 4) 1.5 N m (1.1 ft. lb)
Load type
Maximum load
Probable cause
No power applied
Faulty connection in power supply
Faulty RS-485 cable connection to
network camera
PTZ functionality not enabled in net-
work camera
YP3040 Installation Guide
Description
24 V AC 50/60 Hz
30 VA
0° to 355°
10° to -80°
7.5°/s
6°/s
Pelco-D
2400 bps
1
-20°C to 65°C (-4°F to 149°F)
Top load
10 kg (22 lb)
4.2 kg (9 lb)
IP66 (indoor and outdoor use)
Aluminum alloy
Remedy
Check that power supply is connected
Check that power supply cable is
intact and connected correctly
Check that RS-485 cable is intact and
connected correctly
Check that PTZ functionality is
enabled in Setup tools, see Setup, on
page 7

Advertisement