Axis YP3040 Installation Manual page 9

Pan-tilt motor
Hide thumbs Also See for YP3040:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
YP3040 Installation Guide
About the DIP switch settings
The transmission between the motor and the camera will not work if the camera uses a different
protocol and bit rate than the motor. For cameras with a different protocol than the Pelco-D and
bit rate of 2400 bps, the dip switches must be changed, see Change the DIP switch settings, on page
10.
Note:
The default factory settings of the YP3040 Pan-Tilt Motor are the Pelco-D protocol and a
bit rate of 2400 bps. This means that the DIP switch settings do not need to be changed
when using the motor with an Axis network camera with the Pelco-D protocol.
The YP3040 Pan-Tilt Motor has two sets of 8 digital DIP switches.
Select address
Select function
The 8 switches on the left-hand side are used to select functions such as protocol, bit rate, and
terminal resistance. The 8 switches on the right-hand side are used to select multiple unique
addresses when connecting several units in a series through a multi-channel video server. There are
255 different switch combinations.
Note:
In a typical installation only the one default address is required.
Page 9

Advertisement

Table of Contents
loading

Table of Contents