Empire OLL48FP12S(N,P)-2 Installation Instructions And Owner's Manual

Empire OLL48FP12S(N,P)-2 Installation Instructions And Owner's Manual

Empire oll48fp12s(n,p)-2; oll48sp12s(n,p)-2 gas fireplace
Table of Contents

Advertisement

Available languages

Available languages

OUTDOOR LINEAR GAS FIREpLACE
MODELS
GAS-FIRED
OLL48Fp12S(N,p)-2
OLL48Sp12S(N,p)-2
Installer:
Leave this manual with the fireplace.
Consumer: Retain this manual for future reference.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
If not installed, operated and maintained in accordance
with the manufacturer's instructions, this product
could expose you to substances in fuel or from fuel
combustion which can cause death or serious illness.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Read the installation, operating and maintenance
instructions thoroughly before installing or servicing
this equipment.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
WARNING
WARNING
WARNING
For Outdoor Use Only.
WARNING
If the information in these instructions are
not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
If you smell gas:
1. Shut off gas to the fireplace.
2. Extinguish any open flame.
3. If odor continues, keep away from the
fireplace and immediately call your gas
supplier or fire department.
WARNING
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
An LP-cylinder not connected for use shall
not be stored in the vicinity of this or any
other appliance.
DANGER
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Empire OLL48FP12S(N,P)-2

  • Page 1 INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL OUTDOOR LINEAR GAS FIREpLACE WARNING MODELS For Outdoor Use Only. GAS-FIRED OLL48Fp12S(N,p)-2 WARNING OLL48Sp12S(N,p)-2 If the information in these instructions are not followed exactly, a fire or explosion may Installer: Leave this manual with the fireplace. result causing property damage, personal Consumer: Retain this manual for future reference. injury or loss of life. — Installation and service must be performed by a...
  • Page 2: Before You Start

    BEFORE YOU START Read the safety information on pages 4, 32 and 33. What to consider before installing. See Page 9. Water drainage is required. See page 10. Optional drain tray available. Where are you going to install the unit? See pages 9 to 10. Frame the opening.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SECTION pAGE BEFORE YOU START .....................2 TABLE OF CONTENTS ...................3 INTRODUCTION ......................4 SpECIFICATIONS ....................5 ACCESSORIES .......................5 COMBUSTIBLE MATERIALS .................6 CLEARANCES .....................6-7 FIREpLACE DIMENSIONS ..................8 pLANNING INSTALLATION ................9-11 FIREpLACE FRAMING AND INSTALLATION ..........12-19 FRAMING & INSTALLATION ................12-13 ELECTRICAL SUPPLY ..................14 GAS SUPPLY .....................15 LP-GAS CYLINDER INFORMATION ............16-17 FINISHING ....................18-19...
  • Page 4: Introduction

    Chase platforms, including hearths should slope away from the structure at 1/4 in. per foot. The fireplace can be shimmed level. When installed on surfaces where water may collect or cause damage: Empire Comfort Systems recommends a slope of 1/8 to 1/4 in. per foot towards the drain port suggested. The fireplace can be shimmed level. Page 4...
  • Page 5: Specifications

    SpECIFICATIONS Model OLL48(FP,SP)12SP (Propane) OLL48(Fp,Sp)12SN (Natural) Gas Input BTU/Hr Maximum 55,000 55,000 Gas Input BTU/Hr Medium 45,000 45,000 Gas Input BTU/Hr Minimum 35,000 35,000 Orifice Air Shutter Setting 3/8 in. Open 1/16 in. Open Manifold Pressure 11 in. W.C. 4-1/2 in. W.C. ACCESSORIES DECORATIVE CRUSHED GLASS Required Decorative Crushed Glass Media Kits (8 Sq. Ft. Required for Burner and LED Lighting) Model Description...
  • Page 6 Television Considerations Installing a television above a fireplace has become increasingly popular; however, the area above any fireplace gets hot and most TV manufacturers recommend against placing their products near a heat source. If you install a television above this fireplace, Empire Comfort Sys- tems accepts no responsibility for damage or injuries. Follow the television manufacturer’s installation instructions, including any recommendations regarding proximity to heat sources. If you have a TV above your fireplace, turn off the fireplace and let it cool completely before servicing or touching any buttons on the TV.
  • Page 7 CLEARANCES Figure 4 Front and Side View of Non-Combustible Panel to Opening on Fireplace's Face Note: Recommended installation if using 6 in. or smaller tiles or finishing materials. Figure 5 Front View and Side Profile of Non-Combustible Panel to Top of Fireplace Note: Recommended installation if using 6-in. or larger tiles or finishing materials. Note for Figures 4 and 5: If installing the wall board in the flush face configuration, trim the two top panels to 16-1/2 in. x 26-3/4 in. The smaller non-combustible panels will not be needed. 35305-0-0315 Page 7...
  • Page 8: Fireplace Dimensions

    FIREpLACE DIMENSIONS OLL48Fp OLL48Sp INDEX DIMENSION DESCRIpTION LETTER Dimensions in Inches The maximum height of firebox face (excluding standoffs) 24-5/16 24-5/16 The maximum width of the firebox face (excluding nailing flanges) 51-3/4 51-3/4 The maximum depth of the firebox 19-1/16 22-5/16 The height of the firebox opening 16-3/16 16-3/16 The width of the firebox opening The interior depth of the firebox (not shown) 22-9/32 The rear exterior width of the firebox (not shown) 51-3/4 51-3/4 The height to the firebox standoffs 16-1/2 16-1/2 Width from the left side of the box to the centerline of vent Depth from back of box to centerline of top vent Height from the bottom of the box to the gas line opening 2-9/16 2-9/16 Depth from the front of the box to gas line opening 5-3/16 5-3/16 Depth from rear of box to gas line opening 13-21/32 Glass height 3-1/2 3-1/2...
  • Page 9: Planning Installation

    pLANNING INSTALLATION What to Consider Before Installing Outdoor Fireplace Enclosure Requirements 1. Verify fireplace gas type and gas supply type are the same. Do not install fireplace until all necessary provisions are made for Look for a location where combustibles will not interfere. combustion and ventilation air. Consult the written instructions 120V GFI power outlet will be needed for LED lights provided with the fireplace for information concerning combustion Choose a location for gas shutoff valve. and ventilation air.
  • Page 10 Gas Line Connection Provisions must be made to drain water away from the unit. An The fireplace is designed to accept a 1/2 in. gas line. Have the optional drain pan can be purchased from your Empire Dealer to line installed by a qualified service person in accordance with all fit under the fireplace. If installing the optional drain pan, it must building codes. Consult local building codes to properly size the gas be installed prior to installing the fireplace. For more information,...
  • Page 11 pLANNING INSTALLATION Electrical Considerations CAUTION All wiring should be done by a qualified electrician and shall be in compliance with all local, city and state building codes. Before making the electrical connection, make sure that the main power supply is disconnected. The fireplace, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70 (Latest Edition).
  • Page 12: Fireplace Framing And Installation

    FIREpLACE FRAMING AND INSTALLATION FRAMING & INSTALLATION Unpacking the Fireplace Before completing the framing and installing fireplace, provide a After removal of the cardboard carton, remove the band hold- path for water drainage out of the fireplace. ing the corner posts, non-combustible board and top mounting standoffs to the fireplace. Set the non-combustible board and top Determine if the optional accessory drain pan will be used. See mounting standoffs aside, discard the corner posts.
  • Page 13: Framing & Installation

    FIREpLACE FRAMING AND INSTALLATION FRAMING & INSTALLATION 6. Locate the top standoffs (three for single-sided fireplaces To connect the gas line and install the electrical connection, and six for see-through fireplaces). Bend mounting feet and the burner assembly must be tilted upward in the fireplace. attach to the top of the fireplace with two #10-32x1/2 hex To lift the burner assembly, remove the control door by open- screws each. ing the door and lifting it upward to disengage the slots on the door from the pivot pins..
  • Page 14 FIREpLACE FRAMING AND INSTALLATION FRAMING & INSTALLATION 10. Lift front of burner assembly and tilt upwards and toward the back of the fireplace. Retrieve the two supports from inside the fireplace and place one each side against the front cor- ners of the cabinet bottom and under the front corners of the control panel. PROP SUPPORT IN FOUR CORNERS Figure 19 11. Install gas and electrical supplies to fireplace. See page 16 for gas supply requirements.
  • Page 15: Electrical Supply

    FIREpLACE FRAMING AND INSTALLATION ELECTRICAL SUPPLY CAUTION All wiring should be done by a qualified electrician and shall be in compliance with all local, city and state building codes. Before making the electrical connection, make sure that the main power supply is disconnected. The fireplace, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70 (Latest Edition).
  • Page 16: Gas Supply

    FIREpLACE FRAMING AND INSTALLATION GAS SUPPLY • Solid fuels shall not be burned in this fireplace. into the gas line that is capped on the bottom in which condensation and foreign particles may collect. • The maximum gas inlet supply pressure is 11 in. for LP and 10.5 in. for NAT. The use of the following gas connectors is recommended: —...
  • Page 17: Lp-Gas Cylinder Information

    FIREpLACE FRAMING AND INSTALLATION LP-GAS CYLINDER INFORMATION WARNING WARNING If these instructions are not followed exactly, a fire causing A fire will result if the gas supply hose makes contact with the death or serious injury may occur. underside of the fireplace. Propane Cylinder Specifications LP (Propane) Gas This fireplace can be used with a non-disposable self-contained Attach cylinder retaining bracket supplied to the base of the cyl- LP-gas supply system: inder. Then secure to the surface to which it sits. Cylinder should •...
  • Page 18 FIREpLACE FRAMING AND INSTALLATION LP-GAS CYLINDER INFORMATION Enclosures For LP (Propane) Gas Supply Systems The enclosure for the LP-gas cylinder shall isolate the cylinder Enclosures for LP-gas supply cylinders shall be ventilated by from the burner compartment to provide: openings at the level of the cylinder valve and at floor level. The Shielding from heat radiation; effectiveness of the opening(s) for purposes of ventilation shall b. A flame barrier; and be determined with the LP-gas supply cylinder(s) in place.
  • Page 19: Finishing

    FIREpLACE FRAMING AND INSTALLATION FINISHING After gas and electrical hookup is completed, lower and The fireplace can also be installed with panels flush with the secure the burner assembly (leave two supports in bottom of face of the fireplace. See Figure 27. In this application, the two fireplace for future use) with the two screws removed in Step top non-combustible panels (provided) are required above the 9 on page 13. fireplace. Outside of this area including the sides outside of the 2. Install the glass wind panel (two used on see-through fire- fireplace's metal may be any weatherproof wall board.
  • Page 20 FIREpLACE FRAMING AND INSTALLATION FINISHING Crushed Glass Installation Decorative glass droplets may be added, but can not be used Ensure the burner cover screens are still properly installed, fully near or over the burner. See Figure 29. Neither glass nor droplets covering the LED openings. Place decorative crushed glass over may be placed over the spark probe.
  • Page 21: For Your Safety Read Before Lighting

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXpLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. BEFORE LIGHTING, smell around the appliance area for B. Use only your hand to push in or turn the gas control gas. Be sure to smell next to the floor because some gas knob. Never use tools. If the knob will not push in or is heavier than air and will settle on the floor.
  • Page 22: Main Burner Flame Characteristics

    MAIN BURNER FLAME CHARACTERISTICS Figure 31 - Correct Flame LP Figure 29 WARNING NEVER operate fireplace with an optional weather door in place. Figure 32 - Correct Flame NAT In normal operation on high after 10 to 15 minutes, the flame ap- pearance should be several tongues of yellow flames. NOTE: All flames will be random by design, flame height will go up and down. During manufacturing, fabricating and shipping, various components of this fireplace are treated with certain oils, films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the fireplace. This is a normal and temporary occurrence.
  • Page 23: Operation Instructions/Flame Appearance

    OpERATION INSTRUCTIONS/FLAME AppEARANCE LED Brightness Button Press the Brightness Button to activate the LED lights and to cycle LED Intensity from High to Low to Off. 1 – On – High 2 – Medium 3 – Low 4 – Off Use the Brightness Button in conjunction with the Mode Button to create unique looks.
  • Page 24: Wiring

    WIRING Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. LED STRIP LED STRIP JUNCTION BOX TRANSFORMER BLACK LEFT BUTTON BLACK BLACK BRIGHTNESS BLACK RIGHT BUTTON BLACK BLACK MODE BLACK...
  • Page 25: Maintenance

    MAINTENANCE Keep the control compartment and burner area surrounding the PERIODIC CLEANING – Refer to parts diagram for location of burner clean. items discussed below. • Do not use cleaning fluid to clean any part of fireplace. Always keep the fireplace area clear and free from combustible • Overtime the crushed glass may break down into small pieces materials, gasoline, and other flammable vapors and liquids. that could clog the main burner ports. Remove fine glass Never obstruct the flow of combustion and ventilation air. Keep the particles away from burner ports.
  • Page 26: Troubleshooting

    TROUBLESHOOTING SYMpTOMS - pOSSIBLE CAUSES AND CORRECTIONS Turn fireplace OFF and allow to cool before servicing. Only a qualified service person should service and repair the fireplace. 1. Fireplace produces unwanted odors. 6. If burning at main burner orifice occurs (a loud, roaring a. Fireplace burning vapors from paint, hair spray, glues, etc. blow torch noise). - Ventilate area. Stop using odor causing products while a. You must turn off burner assembly and contact a qualified fireplace is running. service person. b. Gas leak - Locate and correct all leaks. b.
  • Page 27: Master Parts Distributor List

    MASTER pARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort. com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 28 OLL48Fp12S pARTS LIST USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. QTY REQ QTY REQ INDEX pART INDEX pART DESCRIpTION DESCRIpTION BRACKET TOP MOUNT- WIRE HARNESS 34181 R11924 SWITCHES NON-COMBUSTIBLE R1652 NUT LOCK (VALVE) 33663 BOARD R11802 COVER SCREEN LIGHTS R11801 GLASS COVER SCREEN LIGHTS 34225 33242 CONTROL DOOR WITH CUTOUT 34182...
  • Page 29: Oll48Fp12S Parts View

    OLL48Fp12S pARTS VIEW 35305-0-0315 Page 29...
  • Page 30: Oll48Sp12S Parts List

    OLL48Sp12S pARTS LIST USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. QTY REQ QTY REQ INDEX pART INDEX pART DESCRIpTION DESCRIpTION 34181 BRACKET TOP MOUNTING R1652 NUT LOCK (VALVE) NONCOMBUSTIBLE R11802 COVER SCREEN LIGHTS 33663 BOARD COVER SCREEN LIGHT 34225 33548 PANEL WITH CUTOUT R11801 GLASS R11843 CONTROL DOOR SCREW 33242 DOOR CONTROL...
  • Page 31: Oll48Sp12S Parts View

    OLL48Sp12S pARTS VIEW 35305-0-0315 Page 31...
  • Page 32: Important Safety Information

    IMpORTANT SAFETY INFORMATION • Installer: Please leave these instructions with the owner for DANGER: Indicates a hazardous situation which, if not future reference avoided, will result in death or serious injury. • This unit complies with ANSI Z21.97/CSA 2.41 for Outdoor WARNING: Indicates a hazardous situation which, if not Gas Fireplaces.
  • Page 33: Safety Information For Users Of Lp-Gas

    SAFETY INFORMATION FOR USERS OF Lp-GAS Propane (LP-Gas) is a flammable gas which can cause fires SOME pOINTS TO REMEMBER and explosions. In its natural state, propane is odorless and • Learn to recognize the odor of LP-gas. Your local LP-Gas colorless. You may not know all the following safety precautions Dealer can give you a “Scratch and Sniff” pamphlet. Use it to which can protect both you and your family from an accident. find out what the propane odor smells like. If you suspect that Read them carefully now, then review them point by point with your LP-Gas has a weak or abnormal odor, call your LP-Gas the members of your household. Someday when there may not Dealer.
  • Page 34 FIREpLACE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes Page 34 35305-0-0315...
  • Page 35: Warranty Terms

    WARRANTY TERMS Empire Comfort Systems Inc. warranties this hearth product to be free from defects at the time of purchase and for the pe- riods specified below. Hearth products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual. This warranty applies to the original purchaser only and is not transferable. All warranty repairs must be accomplished by a qualified gas appliance technician.
  • Page 36 Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 36 35305-0-0315...
  • Page 37 INSTRUCTIONS D’INSTALLATION ET MODE D’EMPLOI AVERTISSEMENT FOYER À GAZ LINÉAIRE EXTÉRIEUR Pour usage extérieur seulement. MODÈLE GAS-FIRED AVERTISSEMENT OLL48Fp12S(N,p)-2 Si ces instructions ne sont pas respectées OLL48Sp12S(N,p)-2 à la lettre, il peut se produire un incendie ou une explosion causant des dégâts matériels, Installateur : Laisser ce manuel avec le foyer. des lésions corporelles ou pertes de vie hu- Consommateur : Garder ce manuel pour référence maine. ultérieure. DANGER — L’installation et l’entretien doivent être exécutés Si vous sentez du gaz : par un installateur qualifié, une agence de service 1. Coupez le gaz au foyer. ou par le fournisseur de gaz.
  • Page 38 AVANT DE COMMENCER 1. Lire les informations relatives à la sécurité figurant aux pages 4, 32 et 33. Que faut-il prendre en compte avant l’installation. Voir page 9. Il faut prévoir un écoulement d’eau. Voir page 10. Plateau d’écoulement en option. Où prévoyez-vous d’installer l’appareil? Voir pages 9 à 10. Encadrer l’ouverture. Voir les pages 6 à 8 et 12. Installer le foyer.
  • Page 39 TABLE DES MATIÈRES SECTION pAGE AVANT DE COMMENCER ....................2 TABLE DES MATIÈRES ......................3 INTRODUCTION ........................4 SpÉCIFICATIONS ........................5 ACCESSOIRES ........................5 MATÉRIAUX COMBUSTIBLES ...................6 DÉGAGEMENTS ......................6-7 DIMENSIONS DU FOYER ....................8 PLANIFIER L’INSTALLATION ..................9-11 ENCADREMENT ET INSTALLATION DE FOYER ............12-19 CADRAGE ET INSTALLATION .................12-13 ALIMENTATION ÉLECTRIQUE ..................14 ALIMENTATION EN GAZ ....................15 INFORMATION SUR LE CYLINDRE DE GPL ............16-17...
  • Page 40: Introduction

    Contactez le fabricant ou votre société de à l’humidité. gaz avant de changer la taille de l’injecteur/orifice. Lorsqu’il est installé sur des murs extérieurs : Empire Comfort Installations pour le gaz de tête de puits Systems recommande que le caniveau du foyer soit construit à Certaines installations au gaz naturel de type « tête de puits. » Ceci l’extérieur de l’enveloppe d’intempérie. À l’endroit où la plateforme...
  • Page 41: Spécifications

    SpÉCIFICATIONS Modèle OLL48(FP,SP)12SP (Propane) OLL48(Fp,Sp)12SN (Naturel) Entrée de gaz BTU/H maximum 55 000 55 000 Entrée de gaz BTU/H moyenne 45 000 45 000 Entrée de gaz BTU/H minimum 35 000 35 000 Orifice n° 44 n° 24 Réglage d’obturateur d’air 3/8 po ouvert 1/16 po ouvert Pression de collecteur 11 po CE 4 1/2 po CE...
  • Page 42: Matériaux Combustibles

    Si vous installez une télévision au-dessus de ce foyer, soyez avisé que Empire Comfort Systems n’accepte aucune responsabilité en cas de dommage ou blessures. Suivre les directives d’installation du fabricant de télévision ainsi que toutes recommandations se rapportant à la proximité avec les sources de chaleur.
  • Page 43: Dégagements

    DÉGAGEMENTS Figure 4 Vue devant et latérale du panneau non combustible à l’ouverture sur la façade du foyer Remarque : il est recommandé d’installer des tuiles ou des matériaux de finition de 6 po ou plus petits. Figure 5 Vue devant et profil latéral du panneau non combustible au-dessus du foyer Remarque : il est recommandé d’installer des tuiles ou des matériaux de finition de 6 po ou plus grands. Remarque concernant les figures 4 et 5 : si le panneau mural est installé avec la façade affleurante, couper les deux panneaux supérieurs à 16-1/2 po x 26-3/4 po. Les panneaux non combustibles plus petits ne seront pas nécessaires. 35305-0-0315 Page 7...
  • Page 44: Dimensions Du Foyer

    DIMENSIONS DU FOYER OLL48Fp OLL48Sp LETTRE DE DESCRIpTION DE LA DIMENSION RÉpERTOIRE Dimensions en pouces La hauteur maximale de la façade du foyer (excluant les entretoises) 24-5/16 24-5/16 La largeur maximale de la façade du foyer (excluant les brides de clouage) 51-3/4 51-3/4 La profondeur maximale du foyer 19-1/16 22-5/16 La hauteur de l’ouverture du foyer 16-3/16 16-3/16 La largeur de l’ouverture du foyer La profondeur intérieure du foyer (non illustrée) 22-9/32 La largeur extérieure arrière du foyer (non illustrée) 51-3/4...
  • Page 45: Planifier L'installation

    PLANIFIER L’INSTALLATION Ce dont il faut tenir compte avant l’installation Exigences pour boîtier de foyer extérieur 1. Vérifier que le type du foyer au gaz et le type d’alimentation en Ne pas installer le foyer tant que toutes les mesures n’ont pas gaz sont les mêmes. été effectuées à l’égard de la combustion et l’air de ventilation. Trouver un endroit où les combustibles ne risquent pas Veuillez lire les directives écrites livrées avec le foyer pour obtenir d’interférer.
  • Page 46 Faites installer la conduite par une personne qualifiée selon tous taillant Empire qui s’installe sous le foyer. Si un bac d’écoulement les codes en bâtiment. Consulter les codes en bâtiment locaux en option est installé, il faut le faire avant d’installer le foyer. Pour pour installer une conduite d’alimentation de gaz adéquate pour...
  • Page 47 pLANNING INSTALLATION Considérations électriques ATTENTION Tous les câblages doivent être effectués par un électricien qualifié et être conformes à tous les codes du bâtiment locaux, munici- paux et provinciaux en vigueur. Avant d’effectuer le raccordement électrique, s’assurer que l’alimentation électrique principale est débranchée. Le foyer, lors de son installation, doit être élec- triquement relié à la terre en conformité avec la réglementation locale ou, en l’absence de réglementation locale, avec le Code électrique national, ANSI/NFPA 70 (édition la plus récente).
  • Page 48: Encadrement Et Installation De Foyer

    ENCADREMENT ET INSTALLATION DE FOYER CADRAGE ET INSTALLATION Déballage du foyer Avant de terminer l’ossature et d’installer le foyer, fournir un chemin Après avoir enlevé la boîte en carton, retirer la bande qui retient pour éloigner l’écoulement d’eau du foyer. les poteaux de coin, le panneau non combustible et les entretois- es de montage du foyer. Mettre le panneau non combustible et Déterminer si le bac d’écoulement en option sera utilisé.
  • Page 49: Cadrage Et Installation

    ENCADREMENT ET INSTALLATION DE FOYER CADRAGE ET INSTALLATION Repérer les entretoises du dessus (trois pour un foyer à 8. Pour raccorder la conduite de gaz et installer la connexion façade simple et six pour les foyers à deux faces). Plier les électrique, le brûleur doit être incliné vers le haut du foyer. pieds de montage et fixer le dessus du foyer avec deux vis Pour soulever l’ensemble du brûleur, retirer la porte de con- hexagonales n° 10-32 x 1/2.
  • Page 50 ENCADREMENT ET INSTALLATION DE FOYER CADRAGE ET INSTALLATION 10. Soulever le devant de l’ensemble du brûleur et incliner vers le haut et l’arrière du foyer. Récupérer les deux supports à l’intérieur du foyer et placer de chaque côté contre les coins avant au bas de l’armoire et sous les coins avant du pan- neau de contrôle.
  • Page 51: Alimentation Électrique

    ENCADREMENT ET INSTALLATION DE FOYER ALIMENTATION ÉLECTRIQUE ATTENTION Tous les câblages doivent être effectués par un électricien qualifié et être conformes à tous les codes du bâtiment locaux, munici- paux et provinciaux en vigueur. Avant d’effectuer le raccordement électrique, s’assurer que l’alimentation électrique principale est débranchée. Le foyer, lors de son installation, doit être élec- triquement relié à la terre en conformité avec la réglementation locale ou, en l’absence de réglementation locale, avec le Code électrique national, ANSI/NFPA 70 (édition la plus récente).
  • Page 52: Alimentation En Gaz

    ENCADREMENT ET INSTALLATION DE FOYER ALIMENTATION EN GAZ • Les combustibles solides ne doivent pas être brûlés dans ce Poser une vanne de gaz et un raccord à joint rodé sur la conduite foyer. de gaz en amont de la vanne de régulation pour faciliter l’entretien. Il •...
  • Page 53: Information Sur Le Cylindre De Gpl

    ENCADREMENT ET INSTALLATION DE FOYER INFORMATION SUR LE CYLINDRE DE GPL AVERTISSEMENT AVERTISSEMENT Si ces directives ne sont pas suivies avec précision, un in- Un incendie peut survenir si le tuyau d’alimentation en gaz fait cendie peut se déclarer et causer de graves blessures, voire la contact avec le dessous du foyer.
  • Page 54 ENCADREMENT ET INSTALLATION DE FOYER INFORMATION SUR LE CYLINDRE DE GPL Recouvrements pour systèmes d’alimentation en GPL (pro- Le recouvrement du cylindre GPL doit isoler le cylindre du com- pane) partiment du brûleur pour fournir : Les recouvrements des cylindres d’alimentation en gaz GPL dev- Une protection contre la radiation thermique; ront être ventilés par des ouvertures au niveau de la soupape du b. Une barrière contre les flammes; et cylindre et au niveau du plancher. L’efficacité de(s) l’ouverture(s)
  • Page 55: Finitions

    ENCADREMENT ET INSTALLATION DE FOYER FINITIONS Une fois le raccordement du gaz et de l’électricité, baisser et Le foyer peut aussi être installé avec des panneaux affleurants fixer le brûleur (laisser deux supports au bas du foyer pour à la façade du foyer. Voir la figure 27. Dans cette application, les usage futur) avec les deux vis retirées à l’étape 9 sur la page deux panneaux supérieurs non combustibles (fournis) sont requis au-dessus du foyer. Hors de cette zone, incluant les côtés en 2. Installer le panneau vitré (deux utilisés pour le foyer à deux dehors du métal du foyer, peut être en panneau mural résistant faces). Voir figure 24.
  • Page 56 ENCADREMENT ET INSTALLATION DE FOYER FINITIONS Installation du verre pilé Ces morceaux peuvent être utilisés, mais pas sur le brûleur ni S’assurer que les grilles sur le brûleur sont bien installées, autour de la flamme. Voir figure 28. qu’elles couvrent entièrement les ouvertures DEL. Placer le verre On peut ajouter des gouttelettes de verre décoratif, mais elles ne pilé décoratif sur le couvercle du brûleur, la grille et le brûleur doivent pas être ajoutées près ni sur le brûleur. Voir la figure 29.
  • Page 57: Instructions D'allumage

    INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ AVANT D’ALLUMER AVERTISSEMENT NE pAS RESpECTER À LA LETTRE LES INSTRUCTIONS DANS LE pRÉSENT MANUEL pOURRAIT CAUSER UN INCENDIE OU UNE EXpLOSION, ENTRAÎNANT DES DOMMAGES MATÉRIELS, DES LÉSIONS CORpORELLES OU LA PERTE DE VIES HUMAINES. A. AVANT D’ALLUMER, renifler autour de l’appareil pour B. Enfoncer ou tourner le bouton de commande de gaz à la déceler toute odeur de gaz. Renifler près du plancher, main seulement. Ne jamais utiliser d’outil. Si le bouton...
  • Page 58: Caractéristiques De La Flamme Du Brûleur Principal

    CARACTÉRISTIQUES DE LA FLAMME DU BRÛLEUR pRINCIpAL Figure 31 – Flamme correcte de GPL Figure 29 AVERTISSEMENT Ne JAMAIS faire fonctionner le foyer lorsque la porte contre les intempéries en option est en place. Figure 32 – Flamme correcte de gaz natural Lors d’une opération normale à plein régime, après 10 à 15 min- utes, l’apparence de la flamme devrait devenir des ensembles de flammes jaunes.
  • Page 59: Instructions D'opération / Apparence De La Flamme

    INSTRUCTIONS D’OPÉRATION / APPARENCE DE LA FLAMME Bouton de luminosité DEL Appuyer sur le bouton de luminosité pour activer les témoins DEL et pour tourner l’intensité DEL de haute à basse à éteinte. 1 – Allumée – Forte 2 – Moyenne 3 – Basse 4 – Éteinte Utiliser le bouton de luminosité en conjonction avec le bouton de mode pour créer une apparence unique.
  • Page 60: Câblage

    CÂBLAGE Étiqueter tous les fils avant de les débrancher. Les erreurs de câblage peuvent se solder en un mauvais fonctionnement dangereux. Vérifier le bon fonctionnement après toute opération d’entretien. Figure 36 – Câblage du système DEL Figure 37 – Câblage du système allumeur électronique Page 24 35305-0-0315...
  • Page 61: Entretien

    ENTRETIEN Gardez le compartiment de commande et la zone autour du brûleur NETTOYAGE PÉRIODIQUE – Veuillez vous référer au diagramme propre. de pièces pour l’emplacement des articles discutés ci-dessous. • Ne pas utiliser de nettoyant liquide pour nettoyer n’importe Toujours maintenir le voisinage du foyer dégagé et exempt de quelle pièce du foyer. matières combustibles, essence et autres vapeurs et liquides •...
  • Page 62: Dépannage

    DÉpANNAGE SYMpTÔMES - CAUSES pOSSIBLES ET CORRECTION Éteindre le foyer et le laisser refroidir avant d’entretenir. Une fois que la personne de service qualifié devrait servir et réparer le foyer. 1. Le foyer produit des odeurs indésirables. 5. Le brûleur n’allume pas. Le foyer brûle des vapeurs de peinture, aérosols, colles, Ne pas tenir le bouton de contrôle assez longtemps. etc. - Ventiler la zone. Cesser d’utiliser des produits causant b. L’orifice du brûleur est bouché - Nettoyer le brûleur ou des odeurs lorsque le chauffage est en marche.
  • Page 63: Liste Des Distributeurs De Pièces Principaux

    LISTE DES DISTRIBUTEURS DE pIÈCES pRINCIpAUX Pour commander des pièces sous garantie, adressez-vous au revendeur Empire local. Veuillez voir le concessionnaire au www.empirecomfort.com. Pour assurer un service sous garantie, le revendeur doit connaître votre nom, votre adresse, la date d’achat et le numéro de série du produit, ainsi qui la nature du problème.
  • Page 64: Oll48Fp12S Liste Des Pièces

    OLL48Fp12S LISTE DES pIÈCES UTILISEZ EXCLUSIVEMENT DES PIÈCES DE RECHANGE D’ORIGINE. L’UTILISATION DE TOUTES AUTRES PIÈCES POUR- RAIT CAUSER DES BLESSURES OU LA MORT. QTÉ REQ QTÉ REQ RÉF. RÉF. REpÈRE DESCRIpTION REpÈRE DESCRIpTION pIÈCE pIÈCE FERRURE MONTAGE R11916 VALVE MANUELLE GPL 34181 SUR LE DESSUS R11829 VALVE MANUELLE NAT PANNEAU NON COM- MAMELON 3/8 x 3/8 x 1 33663 R8898 BUSTIBLE FER NOIR R11801 VERRE RÉGULATEUR 4,5 po CE...
  • Page 65: Oll48Fp12S Vue Des Pièces

    OLL48Fp12S VUE DES pIÈCES 35305-0-0315 Page 29...
  • Page 66: Oll48Sp12S Liste Des Pièces

    OLL48Sp12S LISTE DES pIÈCES UTILISEZ EXCLUSIVEMENT DES PIÈCES DE RECHANGE D’ORIGINE. L’UTILISATION DE TOUTES AUTRES PIÈCES POUR- RAIT CAUSER DES BLESSURES OU LA MORT. QTÉ REQ QTÉ REQ RÉF. RÉF. REpÈRE DESCRIpTION REpÈRE DESCRIpTION pIÈCE pIÈCE CONNECTEUR MÂLE FERRURE MONTAGE R7195 34181 LAITON SUR LE DESSUS R11916 VALVE MANUELLE GPL PANNEAU NON COM- 33663 BUSTIBLE R11829 VALVE MANUELLE NAT 33548 PANNEAU MAMELON 3/8 x 3/8 x 1...
  • Page 67: Oll48Sp12S Vue Des Pièces

    OLL48Sp12S VUE DES pIÈCES 35305-0-0315 Page 31...
  • Page 68: Informations De Sécurité Importantes

    INFORMATIONS DE SÉCURITÉ IMpORTANTES • Installateur : Veuillez laisser ces instructions avec le DANGER : Indique une situation dangereuse qui, si elle propriétaire pour référence ultérieure. n’est pas évitée, causera la mort ou des blessures graves. • Cette unité est conforme à ANSI Z21.97/CSA 2.41 pour les AVERTISSEMENT: Indique une situation potentielle- foyers à gaz extérieurs.
  • Page 69: Informations De Sécurité Concernant Le Gpl

    INFORMATIONS DE SÉCURITÉ CONCERNANT LE GpL Le propane (GPL) est un gaz inflammable pouvant provoquer Le GPL peut s’accumuler en couches dans les espaces clos et l’odeur des incendies et des explosions. Dans son état naturel, le gaz peut varier avec la hauteur. Puisqu’il est plus lourd que l’air, il pour- propane est sans odeur et sans couleur. Vous pourriez ne pas rait avoir plus d’odeur dans les niveaux inférieurs. Soyez toujours connaître toutes les consignes de sécurité qui pourrait vous sensibles à la moindre odeur de gaz. Si vous détectez une odeur, protéger vous et votre famille d’un accident. Veuillez les lire soin considérez-la comme une fuite sérieuse.
  • Page 70 MAINTENANCE HISTORIQUE DU FOYER Date Nom du distributeur Nom du technicien de service Entretien effectué/notes Page 34 35305-0-0315...
  • Page 71: Garantie

    à l’usine pour mettre en œuvre tout remplacement de pièces sous garantie. Empire met les pièces de rechange à disposition à l’usine. Les frais de port ne sont pas couverts. Si, après s’être adressé au revendeur Empire, le service reçu n’est pas satisfaisant : Consumer Relations Depart- ment, Empire Comfort Systems Inc., PO Box 529, Belleville, Illinois 62222, ou envoyer un courriel à info@empirecomfort.
  • Page 72 Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220 Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez contacter votre revendeur. www.empirecomfort.com Page 36 35305-0-0315...

This manual is also suitable for:

Oll48sp12s(n,p)-2

Table of Contents