Intruder alarm system

Emergency keys

In order to call for a help (the premises must be secured by CMS) press at once two specific keys and hold
them at least 1 second. When emergency alarm occurs, siren starts to sound and alarm message will be
shown on the keypad display.
Fire alarm
Medical alarm –
Panic alarm

Ways of disarming

Disarming can be done by three ways: F-key, entering PIN code, Via Main Menu. Using F-key or entering PIN, all
partitions, which are controlled by User, will be disarmed. After disarming via Menu it's necessary to unmark the partition,
which we don't want to protect. The partition, which will be disarmed, is denoted the
by pressing the
key.
ENT

Disarming by PIN code, when entering the premise

After opening the door, which are protected, the system begins to count the entry delay. During this time it is
necessary to enter PIN code and confirm by pressing the
User, will be disarmed.

Disarming by PIN code, when staying in protected premise

When all partitions are armed and the entry door weren't opened, after entering PIN, all partitions, which
are controlled by User, will be disarmed. Disarming:
When part of partitions are armed and the entry door weren't opened, after entering PIN it is necessary to
make decision either to arm disarmed partitions or to disarm armed ones.
Full disarming :
Partial disarming:
Disarming when staying in protected premise – BB or F0
Nevertheless, are there all partitions armed or not, all partitions, which are controlled by User, will be
disarmed. Disarming :
F-key:
The first partition disarming, when staying in premise - BB1
Nevertheless, are there all partitions armed or not, the first partition, which is controlled by User, will be
disarmed. Disarming:
F-key:
The second partition can be disarmed with BB2, both partitions with BB12

Alarm clearing

If an alarm has occured, on the display appears message "Alarm!!!" with an explanation, what reason
caused it. Alarm LED is turned on, the siren starts to sound and report about alarm is sending to CMS or to
the User. There are 2 ways to clear alarm and turn off red LED:
alarm
1 way – pressing the
armed
After performed alarm clearing action siren stops to sound
the same as was before alarm. If the system has smoke detector and alarm was caused by smoke, which
trouble
was raised by domestic reasons, the system will start alarm, nevertheless it was armed or disarmed. The
only way to clear alarm is possible by bypassing of smoke detector (see 2 page, "Bypassing zone – B").
3
CLR
2 way – entering PIN code.
After performed alarm clearing action siren stops to sound, alarm LED goes off, the system will be disarmed
if it was armed before entering PIN code. When all partitions, which are controlled by User, are disarmed, it's
not recommended to use PIN for alarm clearing, because is possible casual arming.
Event log review – F30, F31
All events, which are concerned with protected premises and status of the system, are stored in the event
log. Reviewing event log:
F-key:
Via Menu:
To display time or date event press the
Electronic notebook (memo) review - F09
alarm
MAS-800
MAS-800
armed
All important contact information (phone No, e-mail) Installer can write out on keypad. Review:
pre-alarm
trouble
F-key:
Via Menu:
+
.
A
1
+
.
B
4
! !
! !
+
.
C
7
, [Disarming]
PIN:
ENT
, [Disarming]
PIN:
ENT
or
F
0
ENT PIN:
ENT
B
.
B
B
1
ENT PIN:
ENT
! !
! !
CLR PIN:
ENT
(ALARMS events),
F
3
0
ENT
ENT
, [1 record]
F
0
9
ENT
[Memo]
, [1 record]
ENT
ENT
MAS-800 (KM20B, KM20BT, KM20GT keypad)
MAS-800 (KM20B, KM20BT, KM20GT keypad)
PIN:
, [All partitions]
ENT
, [Selected parti]
ENT
.
B
ENT PIN:
ENT
! !
! !
.
, alarm LED goes off, the system status remains
F
3
[Event Log]
, [Alarm Event]
ENT
key, next event is selected the
, [2 record]
, [3 record]
, [2 record]
or
keys and this action is confirmed
key. All partitions, which are controlled by
ENT
.
ENT
.
ENT
, [Parts:]
ENT
.
(FAULTS events).
1
ENT
, [PIN:]
ENT
,
, [4 record]
, [5 record]
, [3 record]
, [4 record]
Short user manual
.
ENT
.
PIN:
ENT
key.
.
, [5 record]
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAS-800 and is the answer not in the manual?

Questions and answers

NAJIH
April 15, 2025

Sir, i have a secolink MAS-800, i need a software programming. I search it in google but i did not find. Please send it to me. I have a default in panel keypad.

User image 67febe2c1328f
1 comments:
Mr. Anderson
April 15, 2025

The SECOLink MAS-800 allows software programming using function keys (F-keys), which can be customized during installation for specific needs. Programming can also be done via the Menu by entering PIN codes to access settings such as date and time, temperature correction, and user management.

This answer is automatically generated

Table of Contents

Save PDF