Wear Eye and hand protection when handling chemicals. Always avoid direct
contact with raw chemicals. Read the manufacturers directions for accidental
contact before handling chemicals. Ensure that an eye-rinse facility and an emer-
gency shower are within easy reach. Check at regular intervals for chemical
leaks.

4.10.1 Chemical Connection

The supply compartment on the B&C HE models is located on the front of the machine. Supply
cups can be accessed by opening the dispenser lid. The supply cups can be removed and filled as
desired. Supply compartments are numbered 1,2,3, and 4 from the left of the machine to the right.
Each cup supply will flush when Detergent is programmed in the control. The programmed chem-
ical signal also appears as a 24VAC signal at the external chemical terminal strip for the duration
of each programmed signal.
External supply connections for the B&C HE washer-extractors with the Stainless Steel supply box
are located on rear of the machine at the vacuum breaker. Hose connections should be made via
the threaded connectors. See figure 4.17 on page 31.
1. Remove plugs from base. See figure.
2. Install the supplied chemical nipple, using teflon tape.
Figure 4.15: Steam Service Connection Detail
29