B&C Technologies HE-35 Installation And Operation Manual page 36

Table of Contents

Advertisement

Attempting to obtain power from the machine terminals may damage the ma-
chine circuit and/or the chemical injection system. Consult the chemical injec-
tion supply system instructions for operational details.
Figure 4.19: External Chemical Supply Terminal Block Detail
2. Open manual shut-off water valves to the machine.
3. Press Emergency Stop button.
4. Apply power to the machine.
5. Release the Emergency button.
6. Check the door interlock before starting the machine.
(a) Attempt to start the machine with the door open. The machine should not start with the
door open.
(b) Close the door without locking it and attempt to start the machine. The washer should
not start with the door unlocked.
(c) Close and lock the door and start a cycle. Attempt to open the door while the cycle is in
progress. The door should not open. If the door lock and interlock are not functioning
properly, call a service technician.
7. For testing, select the check cycle by pressing the down arrow on the keypad. Then press the
START key. Run the complete program, checking operation of water inlet valves, drain, and
extract functions. Refer to the A or B Computer Program manual that came with the machine
for further details on the test program.
8. Cylinder rotation must be counter-clockwise in the extract step. If rotation is not correct,
disconnect the power to the machine. A qualified technician must reverse any two leads
between the AC drive and the motor. See figure 4.20 on page 33.
32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

He-65He-45He-110He-85

Table of Contents