Drain Connection - B&C Technologies HP Series Installation And Operation Manual

Hide thumbs Also See for HP Series:
Table of Contents

Advertisement

A drain system of adequate capacity is
essential to the machine performance.
Ideally the water should empty through a 4
inch vented pipe directly into a sump or
floor drain. See figure.
A flexible connection must be made to a
vented drain system to prevent an airlock or
siphon effect. If proper drain size is not
available or practical, a surge tank is
required. A surge tank in conjunction
with a sump pump should be used when
gravity drainage is not possible, such as in
below-ground-level installations.
Before any deviation from specified
Drain connection Size
Drain flow capacity
Minimum drain pit size
Installation

Drain Connection

Drain Sizing
Units
Metric
mm
liters/min
liters
Drain Construction
Rear of machine
Drain Pipe
Steel Grate
Drain Trough
Strainer
Waste Line
21
installation procedures is attempted, the
customer or installer should contact the
manufacturer. Increasing the drain hose
length, installing elbows, or causing bends
will decrease drain flow rate and increase
drain time, impairing machine performance.
If the drain arrangement is inadequate, the
machine will not extract and will not
discharge water properly.
See table below for specific drain
information.
US
HP-65
in
76
gpm
581
gal
388
Machine
HP-125
3
76.2
150
560
150
100
850
212.5
Rear of machine
Vent
Drain Pipe
Waste Line Tee
Waste Line
3