Electrolux GHS607W User Manual page 10

Hide thumbs Also See for GHS607W:
Table of Contents

Advertisement

LPG conversion -
DONG YANG regulator
• Check that the regulator has been fitted to the
gas supply line in the correct orientation, the arrow on
the base of the body indicates the direction of gas flow.
Once these checks have been completed, if the regulator
still fails to perform in a satisfactory manner it should be
replaced.
9. One by one, turn the knobs to minimum and screw in the
bypass screw (accessible when the knob is removed – refer
figure 11) until a small stable flame results. Turn the knob
to maximum and then back to minimum to ensure that the
correct minimum flame
is maintained.
10. Attach the LPG sticker to the cooker, near the gas supply
inlet. Cover the Natural Gas label that is
factory fitted.
Table 3
Injector size (mm)
BURNER TYPE
Small burner
Medium burner
Large burner
Wok burner
Figure 7
Hex nut assembly,
removed from regulator
and insert disassembled
10 LP CONVERSION - DONG YANG Gas Cooktops
NATURAL GAS
(Nominal test point pressure: 1.00kPa)
Gas consumption
1.00
1.35
1.60
1.75
Hex nut
assembly, fully
screwed down
(Nominal test point pressure: 2.60kPa)
Injector size (mm)
(MJ/h)
5.1
0.55
9.0
0.70
12.1
0.90
14.4
1.00
LPG
Gas consumption
(MJ/h)
4.0
6.5
10.7
13.0
Insert oriented for natural
gas operation
Insert oriented for LPG
operation

Hide quick links:

Advertisement

Table of Contents
loading