Master Switch; Interior Light; Controller Operation; Loading Product - Perlick HC Series Installation & Operation Manual

Single door undercounter refrigeration
Table of Contents

Advertisement

Single Door Undercounter Refrigeration Installation & Operation Manual
OPERATION - SINGLE DOOR UNDERCOUNTER CABINETS

Master Switch

All cabinets come equipped with a master power
switch located behind the louvered toe kick. Remove
the toe kick to turn power on or off the the unit.

Interior Light

Door units are equipped with an interior light that
illuminate when the door is opened. The cabinet
also comes equipped with a manual light switch for
displaying the products through a glass door. For
C-Series (HC), ADA-Compliant (HB) and Shallow-
Depth (HD) models, this is located on the back wall
left of the light.
Always ensure that the manual light switch is in the
OFF position before closing a solid wood or stainless
steel door. If manual light switch is left on for an
extended period of time, it may increase the cabinet
temperature, and cause the refrigeration system to
run harder.

Loading Product

Before storing perishables, turn unit on and allow
it to operate for a minimum of 24 hours to allow
temperatures to stabilize.
When loading items into the unit, do not block internal
louvers and fan guard openings or performance will
be decreased.

Digital Temperature Control

Perlick Single Door Freezer units come standard with
digital control (Figure 5).
Figure 5. Digital Controller
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
The following are the programming button definitions:
SET button
DEFROST button (melting snowflake)
UP arrow
DOWN arrow
ON/OFF button
Digital Controller Operating Instructions
To Set Target Temperature: Press and release the
SET button. Display will show the current temperature
set point.
To Change Setpoint Temperature
1. Press and hold the SET button until the display
shows the current setpoint temperature with the
"F" flashing.
2. Use the UP and DOWN arrow button to scroll to
the desired temperature.
To Start A Manual Defrost (Freezer Models Only)
Press the DEFROST button (melting snowflake)
To Set Maximum Stored Temperature: Press the UP
arrow button to see the maximum stored temperature.
To reset the maximum stored temperature, while
displayed, press and hold the SET button until 'rst'
flashes in the display.
To Set Minimum Stored Temperature: Press
the DOWN arrow button to see the minimum
stored temperature. To reset the minimum stored
temperature, while displayed, press and hold the SET
button until 'rst' flashes in the display.
On/Off: Press the ON/OFF button to turn the unit on
or off.