Installation menu

Symbol:
To access this Configuration menu, press the MODE-button, the OK-button and SET-button at the
same time until Installer menu is shown in the display. Press ESC-button to go to previous Menu.
The adjustments in this menu are only for experts.
All possibilities for adjustment are shown with a self-explaining, floating real text in the display.
Use lower +/– buttons to navigate through menus.
Use upper +/– buttons to change values and OK to confirm.
Following adjustments are possible:
High Temp (HIT):
Low Temp (LOT):
Frost protection (FRT):
Regulation (REG):
Differential (DIF):
Keypad Lock (LOK):
Operating hours (OPT): this feature shows total operating running time (max. 99.999 hours)
Battery Level (BAT):
Warranty
This control is guaranteed against manufacturing defect for a period of 12 months from the date of
installation.
This Guarantee does not cover replacement of batteries or cosmetic damage to the controller.
ATAG Heating Technology Ltd
47 Castle St, Reading, Berkshire, RG1 7SR
Tel: 0800 254 5061
www.atagheating.co.uk
set maximum temperature value for programming from low temperature
value up to +32° C (default: +32° C)
set minimum temperature value for programming from +7°C up to high
temperature value (default: +15° C)
set anti-freeze minimum temperature value from +3° C to +7° C (default: 5°C)
possibility to select between PID or 2 points regulation (default: PID)
possibility to modify differential value from 0,1 K to 0,9 K (default: 0,4 K)
enable keypad to protect against non authorized interventions
To enable/disable the keypad lock press and hold MODE- and ESC-button
for more than 3 seconds.
battery charge level is shown on display
Rev: 02/15/004