Install The Log Set; Connect Gas Supply Line - Vermont Castings OXDV30NV Homeowner's Installation And Operating Manual

Oxford direct vent / natural vent gas heater
Table of Contents

Advertisement

Oxford Direct Vent / Natural Vent Gas Heater
Attach the first section of venting to the draft hood. De-
pending on the length of the individual venting sections
and the lengths of the decorative pipe (if installed), you
may need to slip the decorative pipe over the venting sec-
tions before attaching upper sections to lower ones. The
sections of decorative pipe should be oriented with their
seams (if any) toward the wall; sections usually do not
need to be fastened at each joint, other than slip sections.
If the layout includes a slip section, this should be the last
section of pipe visible in the room, at the ceiling. Complete
the venting according to the vent maker's instructions.
Fig. 33 Install draft hood adapter.

Install the Log Set

1. Remove the logs from their packaging, and inspect
ST767
each piece for damage. DO NOT INSTALL DAM-
DW
AGED LOGS.
attach draft hood
2. Install the rear log centering it side to side on the sheet
5/15/03 djt
metal shelf at the back of the firebox. (Fig. 34) The log
will touch both sides and the back wall of the firebox.
3. Install the right log by engaging hole on bottom with
pin on the rear log. (Fig. 34) Then set right bottom side
on the burner so the edge of the log touches the right
side of the firebox. The right log does not use the loca-
tor pins on the burner to stay in place.
4. Install the left log by engaging hole on bottom with pin
on rear log. (Fig. 34) Then set left bottom side on the
burner so the edge of the log touches the left side of
the firebox.
5. Loosely sprinkle the lava rocks directly on top of the
burner in front of and between the decorative grate
and the right and left logs. Use the lava rock to cover
brackets on the burner. (Fig. 35)
20
Left Log
Rear Log
Fig. 34 Install the back, left and right logs.
connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the
firebox, to confirm that you have the appropriate firebox
for the type of fuel to be used. The Oxford may be con-
verted from one gas to another using the appropriate Fuel
Conversion Kit listed on Page 34.
ST767
This appliance should only be connect-
ed by a qualified gas technician. Test to
confirm manifold pressures as specified
below.
The heater and its individual shutoff valve must be
disconnected from the gas supply piping during
any pressure testing of that system at test pres-
sures in excess of 1/2 psig (3.5 kpa).
The heater must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas supply piping system at test pressure equal to
or less than 1/2 psig.
There must be a gas shutoff between the stove and
the supply.
In order to connect Natural Gas, use a fitting with
3/8" NpT nipple on the valve side and 1/2" natural
gas supply line with an input of 28,000 BTUs at a
manifold pressure of 3.5" and minimum inlet sup-
ply for adjustment of 5.5" w.c.
In order to connect propane, use a fitting with 3/8"
NpT nipple on the valve side and 1/2" propane gas
supply line with an input of 28,000 BTUs at a mani-
fold pressure of 10.0" and minimum inlet supply
for adjustment of 11.0" w.c.
Decorative Grate
LG141
Stardance
Install logs 1
cAUTION
12/11/00 djt
Right Log
LG141
30005123