Battery is easily flammable and vaporized. Keep away from
WARNING
the spark and fire. Charge the battery in the place with good
ventilation.
Electrolyte contains sulfuric acid which may burn the skin
and eyes. Please wear mask and protective clothes.
(1) If the electrolyte splashes to skin, wash off by water at
once
(2) If the electrolyte splashes to eyes, please wash it by water
at least 15 minutes, then go to hospital quickly.
If electrolyte is swallowed, please drink much water and milk,
magnesia or vegetable oil and go to hospital.
Please charge in the place out of the reach of children.
6.3 Overload DC circuit may result in the protector tripping. In this condition,
please disconnect DC load and press the reset key on control panel.
6.4
For electrical equipment, Large current will be generated when the
motor drving system starts.
ON
OFF
-
-
6. GENERATOR USE
To prevent electrical shock from faulty appliances, the
WARNING
generator should be earthed. Connect a length of heavy wire
between the generator's earth terminal and an external ground
source.
Connections for standby power to a building's electrical
system must be made by a qualified electrician and must
comply with all applicable laws and electrical codes. Improper
connections can allow electrical current from the generator to
backfeed into the utility lines. Such backfeed may electrocute
utility company workers or others who contact the lines during
a power outage, and when utility power is restored, the
generator may explode, burn, or cause fires in the building's
electrical system.
Do not overload.
WARNING
Do not exceed the current limit specified for any one
receptacle.
Do not connect the generator to a household circuit. This
could cause the damage to the generator or to electrical
appliances in the house.
Do not modify or use the generator for other purposes than
it is intended for. Also observe the following when using the
generator.
A. Do not connect generators in parallel.
B. Do not connect an extension to the exhaust pipe.
When an extension cable is required, be sure to use a
tough rubber sheathed flexible cable.
Limit length of extension cables:
2
mm
100m for cables of larger than 2.5 mm and the current
capacity within 5A/ mm .
60 m for cables if 1.5