Recessed Installation - Montigo R420 Installation Manual

R-series indoor residential fireplace
Table of Contents

Advertisement

Recessed Installation:

This fireplace can be recessed into the floor to get the viewing area as low as possible.
Maintain a minimum of 6" clearance from the bottom of glass to completed floor. Minimum clearance can be reduced to 3" for uncarpeted
Picture of Non combustible Header
flooring. Discolouration may occur due to high temperatures.
Steel header
(supplied by Montigo)
1" clearance
1" clearance
Figure 6. Recessed Fireplace installation
Note: Images are shown without screens for clarity purposes.
However, your fireplace should not be operated without proper
installation of screens.
XG0770 - 150105.1
Installation
2 x 4
(horizontal)
2 x 4
(horizontal )
2 x 4
(Vertical)
R320 & R420 Power Vent Indoor Gas Fireplace
2-pcs 2 x 4 (vertical)
Both Sides Typ.
1" clearance
6" clearance
1" clearance
1" clearance
Recessed Floor
Page 13