Baxi Platinum Combi 24 HE Installation & Servicing Instructions Manual page 35

Gas fired wall mounted condensing combination boiler
Table of Contents

Advertisement

Venturi
Injector
Gas Inlet Pipe
Fig. 49
Injector
Collector
Fig. 48
Cover
Fan
Venturi
Fig. 50
When fitting the venturi
ensure that the arrow is
pointing forward
12.0 Changing Components
12.3
1. Undo the nut on the gas inlet pipe to the venturi (Fig. 49)
and pull the sensing pipe off the fan.
2. Disconnect the electrode leads, noting their position and
disconnect the fan electrical plugs.
3. Undo the screws securing the collector to the extension
piece.
4. Remove the collector and fan assembly, being careful to
retain the injector in the venturi.
5. Undo the screws securing the fan to the venturi and fit the
new fan, replacing the seal if necessary.
6. Examine the burner gasket and replace if necessary.
7. Reassemble in reverse order, ensuring that the injector is
in place and the sensing pipe is connected to the fan.
12.4
1. Remove the collector and fan assembly as described in
section 12.3.
2. Extract the injector from the venturi.
3. Undo the screws securing the fan to the venturi and the
venturi to the collector.
IMPORTANT: When fitting the new venturi, ensure the
arrows on it's base point into the collector (Fig. 50).
4. Examine the seals and burner gasket, replace if necessary.
Gas Inlet
5. Reassemble in reverse order, ensuring that the injector is
in place.
12.5
1. Remove the collector and fan assembly as described in
section 12.3.
2. Extract and replace the injector and reassemble in reverse
order.
Fan (Fig. 48)
Venturi (Fig. 48)
Injector (Fig. 48)
35