Baxi Duo-tec Combi HE A Range User Operating Instructions Manual

Baxi Duo-tec Combi HE A Range User Operating Instructions Manual

Gas fired wall mounted condensing combination boiler
Hide thumbs Also See for Duo-tec Combi HE A Range:

Advertisement

User's Operating Instructions &
Important Warranty Information
Duo-tec Combi HE
Range
A
Gas Fired Wall Mounted Condensing

Combination Boiler

Baxi Duo-tec Combi 28HE achieved the top score
of 34 boilers tested in a recent Which? report.
Please keep these instructions in a safe place.
If you move house, please hand them over to the next occupier.
© Baxi Heating UK Ltd 2008

Advertisement

Table of Contents
loading

Summary of Contents for Baxi Duo-tec Combi HE A Range

  • Page 1: Combination Boiler

    Baxi Duo-tec Combi 28HE achieved the top score of 34 boilers tested in a recent Which? report. Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. © Baxi Heating UK Ltd 2008...
  • Page 2 the nation’s favourite PLUMBING & HEATING SUPPLIES FREE SHIPPING SECURE PAYMENTS on all orders over £100 to mainland UK shop online with confidence FINANCE AVAILABLE PRICE MATCH spread the cost with low interest rates always get the best deals available we have H U G E R E D U C T I O N S...
  • Page 3: Table Of Contents

    Emergency Warranty & Service © Baxi Heating UK Ltd 2008 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any retrieval system of any nature (including in any database), in each case whether...
  • Page 4: Quick Reference Guide

    Central Heating System Pressure - The normal operating water pressure is between 1 and 2.0 bar. If the pressure exceeds 3 bar the safety pressure valve will operate and a fault is indicated. Contact your Installer. © Baxi Heating UK Ltd 2008...
  • Page 5: Troubleshooting

    ? If the reading falls below 1 bar repressurise the system as Turn the ON/OFF/Reset described in section 3.1. Selector Switch to Reset. If boiler does not Reset Error Code E119 showing low pressure. © Baxi Heating UK Ltd 2008...
  • Page 6 INSTALLER OR SERVICE ENGINEER. If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible. © Baxi Heating UK Ltd 2008...
  • Page 7: Repressurising System

    Requires 8. Disconnect the copper pipe from the taps (a small Repressurising amount of water may be present) and remove it. Keep the pipe in a safe place for future use. © Baxi Heating UK Ltd 2008...
  • Page 8: Clearances

    450mm Min would affect the operation of your boiler. Your installer should have insulated any exposed pipework. For Servicing Purposes 5mm Min Fig. 4 In Operation © Baxi Heating UK Ltd 2008...
  • Page 9: Care Of The Boiler

    5 E133 Interruption Of Gas Supply or Flame Failure seconds. If the boiler does not relight, or the code is displayed E160 Fan or Fan Wiring Fault regularly contact your installer or service engineer. © Baxi Heating UK Ltd 2008...
  • Page 10: Legislation

    Checklist will be required in the event of any warranty work. Keep the instructions in a safe place and ensure that the Service Interval Record at the back is completed at each service visit. © Baxi Heating UK Ltd 2008...
  • Page 11: Notes

    7.0 Notes © Baxi Heating UK Ltd 2008...
  • Page 12: Emergency

    Fig. 7 towards the wall (Fig. 8). 3. Call your Installer or Service Engineer as soon as possible. Heating Flow, Heating Return and Mains Water Inlet Isolating Valves © Baxi Heating UK Ltd 2008...
  • Page 13: Warranty & Service

    Standard Warranty Terms & Conditions To activate your second year free warranty you must register your boiler with heateam the service division of Baxi Heating UK Ltd either by completing and returning the registration card or calling our telephone registration line on 0800 731 1599.