Summary of Contents for Baxi Main Combi 25 Eco

  • Page 1 Combi Eco User’s Guide and Range Important Warranty Information Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. © Baxi Heating UK Ltd 2010...
  • Page 2: Table Of Contents

    Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.centralheating.co.uk © Baxi Heating UK Ltd 2010 All rights reserved. No part of this publication may be reproduced or transmitted in any form or by any means, or stored in any...
  • Page 3: Quick Reference Guide

    GREEN section of the gauge, between 1 and 2.5 bar. If the pressure exceeds 3 bar (needle in the RED section) the safety pressure valve will operate and a fault is indicated. Contact your Installer. © Baxi Heating UK Ltd 2010...
  • Page 4: Troubleshooting

    If the reading falls below 1 bar repressurise the system as Turn the ON/OFF/Reset described in section 3.1. Selector Switch to Reset. If boiler does not Reset Reset Error Code E119 showing low pressure. © Baxi Heating UK Ltd 2010...
  • Page 5 INSTALLER OR SERVICE ENGINEER. If you don’t know what you need to do to get the boiler to light, or need help with the system and controls, contact your installer as soon as possible. © Baxi Heating UK Ltd 2010...
  • Page 6: Repressurising System

    9. Disconnect the flexible pipe from the taps (a small amount of water may be present) and remove it. Keep the pipe in a safe place for future use. Flexible Hose Fig. 3 Taps © Baxi Heating UK Ltd 2010...
  • Page 7: Intelligent Pre-Heat' Feature

    9. Once the Temperature Control is turned approximately 30° clockwise (Fig. 5) the pre-heat feature is activated. 10. Bewteen 30° and fully clockwise the hot water temperature can be altered from 40° and 60° C. Fig. 6 © Baxi Heating UK Ltd 2010...
  • Page 8: Clearances

    450mm Min would affect the operation of your boiler. Your installer should have insulated any exposed pipework. For Servicing Purposes 5mm Min Fig. 8 In Operation © Baxi Heating UK Ltd 2010...
  • Page 9: Care Of The Boiler

    Fan or Fan Wiring Fault selector switch to the reset position and hold for at least 5 seconds. If the boiler does not relight, or the code is displayed regularly contact your installer or service engineer. © Baxi Heating UK Ltd 2010...
  • Page 10: Legislation

    Checklist after each service. 4. The Benchmark Checklist may be required in the event of any warranty work and as supporting documentation relating to home improvements in the optional documents section of the Home Information Pack. © Baxi Heating UK Ltd 2010...
  • Page 11: Emergency

    (Fig. 10). 3. Call your Installer or Service Engineer as soon as possible. Fig. 10 Heating Flow, Heating Return and Mains Water Inlet Isolating Valves © Baxi Heating UK Ltd 2010...
  • Page 12: Warranty & Service

    12 Months Free Warranty - register today To receive your 12 months free warranty please complete the form supplied with the boiler or simply call heateam, the service of Baxi Heating UK Ltd on 0800 731 1644. Our promise to you...