Pre-Installation
f

eatures

Installation Options
Manufactured (Mobile) Home
N atural Gas Or Propane (LP)
Bedrooms
Optional Wall-mounted Or Remote Thermostat
Electrical
The standard fan motor requires 120 Volts AC for operation.
The fireplace is not dependent on the fan or an outside elec-
trical supply to operate. WARNING - Electrical Grounding
Instructions - This appliance is equipped with a three-prong
(grounding) plug for your protection against shock hazard
and should be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove the ground-
ing prong from this plug.
Millivolt Valve
This insert is operated with a millivolt valve and therefore
burns even during a power outage.
Fuel
This insert comes from the factory equipped to burn natural
gas at a specified elevation. The insert can be converted
to burn LP (liquid propane) by installing a conversion kit.
Only Lennox Hearth Products conversion kits can be used
to convert from NG to LP or LP to NG. Contact your Lennox
Hearth Products dealer for details.
RATINGS
Max/Min Input BTUh 0-,000 Feet
(0-10 M)
u
Manifold Pressure (IN. WC)
Min. Inlet Pressure (IN. WC)
Maximum heat output BTUs/hour-
steady state (depending on vent
configuration)
v
P4 Efficiency
Orifice (DMS) 0-,000 Feet (0-10
M)
u
uUnit factory equipped for 0-000 FT/0-10 M, In Canada 0-4500 FT/0-1370 M
vThe Steady State Efficiency numbers based on maximum vent configuration.
wTested to CSA P.4.1-0 "Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 10 VAC, 0 HZ, Less Than  Amps

Ravenna 40 (RDV40)
NATURAL GAS
40,000/8,000
3.5
5.0
83%
7.17%
w
1/8"
p
l
aCkaging
ist
To install a Ravenna™ insert, an insert body, face, surround
(flange) kit, and brick panel are required.
Insert Body Packaging List
1 Insert Body with Burner Cassette
1 Set of Refractory Brick Panels
1 Log Set
1 Ravenna 40
1 #36 Burner Orifce (to convert to Ravenna 33)
1 Bag of Embers
1 Fasteners: 6 slotted 1/4" truss screws
6 speed nuts
9 spring clips
3 plastic adhesive wire restraints
1 Installation and Operation Manual
Decorative Faces - One Required
Traditional
Foundry
Cast pillar
Surround Kits - One Required
Traditional 1-pc. (41"W x 9"H)
Traditional 3-pc.(41"W x 9"H, 48"W x 9"H, 41"W x
33"H or 48"W x 33"H)
Cast Iron (45-1/"W x 30"H-Cast Pillar face only)
Surround Kit Contents
1 Top Surround
2 Side Surrounds
3 Gold or Nickel Plated Trim Pieces
2 Elbowed Trim Fasteners
LP GAS
NATURAL GAS
37,500/,000
33,000/4,000
10.0
10.5
83%
9.07%
#49
Arch inset
Screen
Ravenna 33 (RDV33)
LP GAS
33,000/4,000
3.5
10.0
5.0
10.5
83%
83%
5.55%
7.80%
#3
#51

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite ravenna 33Elite ravenna 40Elite rdv33Elite rdv40

Table of Contents