Component Testing Procedures
To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Illustration
Timer 6 minute
2
4
3
1
Control
1
CN3
CN1
12
1
8
Touch panel
COOK
OZ
HEATER
T/table OFF
10 PROGRAM PADS
1
TIME
ENTRY
2
HOLD
3
0 %
DEFROST
4
20 %
MEDIUM
50 %
5
MED- HI
70 %
6
QTY
7
2X
8
STOP
RESET
9
START
0
3 COOKING STAGES
©2004 Maytag Appliances Company
!
Component
Disconnect wire from terminals.
Measure resistance of the following
terminals:
Terminal 3 to terminal 4 (timer motor) .....
Terminal 1 to terminal 2(timer switch) .....
CN1
Pin 1 (black) to Pin 3 (white) .......................
RY2 (Cook Relay)
Unplug oven and remove wire leads from
RY2 terminals. Connect ohm-meter leads
to terminals.
Plug oven into power supply......................
Initiate cook cycle......................................
NOTE: RY2 should cycle when using
reduced power levels.
RY3 (Fan Relay)
Unplug oven and remove wire leads from
RY3 terminals. Connect ohm-meter leads
to terminals.
Plug oven into power supply......................
Initiate cook cycle......................................
NOTE: Fan relay remains energized for 60
seconds following cook cycle.
Continuity is indicated as 100
Each pad must be pressed to perform the
following test.
16023053 Rev. 0
WARNING
Test
Ω
and below.
1
2
3
4
5
6
7
8
9
10
11
Results
Ω
Approximately 11 K
⎯
Ω
Timer OFF
infinite
⎯
Ω
Timer ON
< 1
Line voltage input to control
transformer.
Ω
Infinite
Ω
< 1
Power levels for Relay 2
Power
Cycles
Cycles
Level
On for:
Off for:
20%
3 sec
9 sec
50%
6 sec
6 sec
70%
9 sec
3 sec
100%
12 sec
0 sec
Ω
Infinite
Ω
< 1
Pad
Trace
Measurement
1
2 & 8
Continuity
2
3 & 8
Continuity
3
4 & 8
Continuity
4
5 & 8
Continuity
5
6 & 8
Continuity
6
7 & 8
Continuity
7
1 & 9
Continuity
8
2 & 9
Continuity
9
3 & 9
Continuity
0
1 & 8
Continuity
Hold
1 & 10
Continuity
Defrost
2 & 10
Continuity
Medium
3 & 10
Continuity
MED-HI
4 & 10
Continuity
Time Entry
5 & 10
Continuity
Stop/Reset
6 & 10
Continuity
Start
7 & 10
Continuity
17