Description of the machine
Programme sequence and check lights
On
Drying
Cool air
Anti-crease/End
Check venting
Check fluff filter
Fault messages
Faults or interruptions are indicated by the se-
quence lights or the "check" lights flashing.
Heating
(flashes)
Safety period
(flashes
)
Gas/Venting
(lights up)
Fluff filter
(lights up)
The messages are:
"Heating"
Fault in the heating system.
Action: Please inform the Service department.
"Safety period"
The maximum running time of the drying pro-
gramme was exceeded because the residual
moisture at the start of the programme was
too high.
Action: Where the residual moisture was too
hight start the drying programme again.
If the fault message occurs again please call
the Service department.
"Venting"
The venting duct is blocked or badly restricted.
Action: Check the vent ducting and if
necessary clean it.
"Fluff filter"
The fluff filter is clogged.
Action: Clean the fluff filter at the end of the
programme.
Note:
The "Drying", "Cool air" and "Anti-crease" indi-
cator lights flash if there is a power cut or if a
programme has been interrupted (e.g. when a
door has been opened and shut). They are
not indicative of a fault. The lights will stop
flashing when the "Start" button is pressed.
This only applies to gas heated machines.
"Gas"
The gas check light comes on when:
– The site gas supply to the machine is inter-
rupted (e.g. gas stop valve has not been
opened).
Action: Open the gas stop valve.
– The gas connection pressure is too low
(there may be a drop in pressure in the gas
supply network).
Action: Inform your gas supplier.
The dryer cannot be switched on again
until the correct gas connection pressure
has been re-established.
– The venting duct is blocked or badly re-
stricted.
Action: Check the venting duct and clean if
necessary.
If the gas / venting check light remains on
after these measures have been taken the
Service department must be called to deal
with the fault.