  • Page 1: Table Of Contents

    Table of contents INLEIDING INSTALLATION INSTRUCTIONS NSTRUCTIONS ENERAL REQUIREMENTS MONTAGE INSTRUCTIES AS TAP LECTRIC POINT LEXIBELE CONNECTION OF GAS CONTROL UNIT TO BURNER SSEMBLY OF THE MANUAL GAS CONTROL UNIT ASSEMBLY OF THE ULTRASONIC GAS CONTROL UNIT SSEMBLY OF THE RADIOGRAFIC GAS CONTROL UNIT OSITIONING OF THE CHIPS AND LOGS XTRA ACCESOIRES 2.8.1...
  • Page 2: Inleiding

    4.3.2 XTINGUISHING THE BURNERS Inleiding DIMENSIONS The open gas log fire from the TWIN series of the brand KAL- TROUBLE SHOOTING FIRE you have purchased is a product of which you will enjoy great pleasure in heating year after year. We recommend checking the appliance at delivery for possible transport - TWIN OLUTIONS FLOWCHART...
  • Page 3: Installation Instructions

    Prior to connecting the gas log fire, please carefully observe the thermal shut off safety or oxistop. following instructions: * A fan suitable for evacuation of flue gasses has to be used. Kal-Fire • Connecting of this gas log fire must be carried out exclusively by a recommends the EXHAUSTO-RSVG-fans (Inatherm).
  • Page 4: Montage Instructies

    Assembly instruction electric wiring Montage instructies This remote control is mains independent. The system runs on batteries. Insert the accompanying 9V block battery into the small transmitter. ATTENTION: All parts have to be mounted maintenance friendly. All parts have to be accessible at all times for the maintenance Insert the 4 accompanying 1.5V penlight batteries into the battery compartment of the receiver: please pay attention to the correct polarity service !!!
  • Page 5 • Test leak tightness of the system by means of soapsuds or leakage ATTENTION: This receiver has tob e mounted outside of the testing spray. burner’s radiation area, because of the sensitiveness of the • Check the protection system by activating the security; the appliance lectronics to heat radiation ! should go out.
  • Page 6: Positioning Of The Chips And Logs

    Positioning of the chips and logs The logs must be positioned as follows: For the TWIN 50x15: Caution ! This is the set of logs you have received: The chips must not cover the holes which are situated at the front of the burner. The safety flame must be in direct contact with these holes otherwise burner...
  • Page 7: Extra Accesoires

    For the de TWIN 80x15: Extra accesoires This is the set of logs you have received: 2.8.1 Optional set of logs For the TWIN 5015 extra accessoires can be ordered. It is possible to order an optional set of logs. This is the optional set of logs: The set of logs is to be positioned as follows: 2.8.2...
  • Page 8: Technical Data

    Technical data There are 2 types of sunken casings available: Sunken casing 75 3.1 TWIN 38 * 15 Model BE/FR AT/CH/GB/IT Propaan Type B11 / B21 B11 / B21 B11 / B21 B11 / B21 B11 / B21 Gas / P G20 / 20 mbar G20 / 20 mbar G25 / 25 mbar...
  • Page 9: Operating Instructions

    Operating instructions Now release the knob (1). If the pilot light does not keep burning, wait for 3 minutes and then repeat the above steps. The TWIN gas log fire’s are available with three types of controls. There are appliances with manual control, ultrasound remote control and radio Now turn the knob (1) fully in the opposite direction, as far as the remote control.
  • Page 10: Extinguishing The Burners

    Appliances with ultrasound remote control Now release the knob (3). If the pilot light does not keep burning, wait for 3 minutes and then repeat the above steps. 4.2.1 Lighting the burners Now turn the knob (3) fully in the opposite direction, as far as the Make sure the gas tap is turned on.
  • Page 11: Extinguishing The Burners

    Appliances with radio remote control If the automatic burner unit (Figure 16) is accessible, this can be reset by pressing in a reset knob (3). You can see that this is locked Take the battery-protection strip out of the manual transmitter and check by the red lamp (3).
  • Page 12: Dimensions

    Reposition them and try again Check the flue connection: does The TWIN burns very blue. this comply with Kal-Fire’s Contact your dealer (It needs ±30 minutes in installation conditions? order to heat up...
  • Page 13: Solutions Flowchart - Twin Ultrasound

    The TWIN burns very blue. Check the flue connection: does Check the flue connection: does The TWIN burns very blue. (It needs ±30 minutes in this comply with Kal-Fire’s this comply with Kal-Fire’s Contact your dealer Contact your dealer (It needs ±30 minutes in...
  • Page 14: Warranty Certificate

    Customer :_________________________ The warranty period for Kal-Fire gas appliances is 1 year starting on the date of purchase which must be clearly and distinctly stated on the sales invoice. The attached warranty Street :_________________________ registration card should be carefully completed and returned to Kal-Fire B.V.
  • Page 15: The Warranty Is Not Applicable In The Following Cases

    Annex 1: Outlet area’s The warranty is not applicable in the following cases: 0,8 m For appliances with remote control: when the electronics are not installed outside the fire and its radiation range, and are not installed to be fully insulated. If the above requirements are not, or are only partially, satisfied.
  • Page 16: Annex 2: Electrical Connection With Fan

    Annex 2: Electrical connection with fan Annex 3: Grafic for calculation flue duct Connection diagram with Inatherm RSVG and EFC21 control unit • With thermal reflux safety cut-out Inatherm Chimney Fan • With controlled ventilation regulator Pressure differential Honeywell S4565DF1068 Inatherm EFC21 X1.1 POWER...