KAL-FIRE Fera series Installation And Operating Instructions Manual

Fera series closed gas fire

Advertisement

Fera closed gas fire
Contents
1
1.1
.
1.2
1.2.1
1.2.2
R
OOFDUCT
1.2.3
.
1.3
1.4
1.5
1.5.1
60
1.5.2
F
75
ERA
1.5.3
75
1.5.4
105
1.5.5
140
2
2.1
2.2
60, 75
105
2.2.1
2.2.2
/
2.2.3
2.2.4
M
OUNTING THE CONVECTION SET FOR THE
2.2.5
2.3
2.3.1
2.4
2.4.1
A
F
H
SSEMBLING THE
ERA
ASTE AND BLUE STONE MANTLE
2.5
F
60
ERA
2.5.1
60
2.6
2.6.1
3
3.1
M
ANUALLY CONTROLLED APPLIANCES
/
F
60 U
,75 U
75
ERA
NI
NI AND
CORNER
.
2
4
5
6
8
8
9
10
10
12
13
13
13
13
14
14
15
16
16
16
17
23
23
24
24
25
26
26
28
28
29
29
30
30

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Fera series and is the answer not in the manual?

Questions and answers

Summary of Contents for KAL-FIRE Fera series

  • Page 1: Table Of Contents

    Contents INTRODUCTION INSTALLATION INSTRUCTIONS LUE REQUIREMENTS XAMPLE OF DUCT 1.2.1 WALLDUCT 1.2.2 OOFDUCT 1.2.3 OOFDUCT FOR EXISTING FLUE YSTEM CALCULATION ESTRICTOR PLATE ECHNICAL DATA 1.5.1 1.5.2 1.5.3 CORNER 1.5.4 1.5.5 BUILDING-IN INSTRUCTIONS Installation and operating instructions HOICE OF MATERIAL 60, 75 2.2.1 HE CONNECTIONS 2.2.2...
  • Page 2: Introduction

    XTINGUISHING THE BURNERS The closed built-in gas fire which you have just purchased from PPLIANCES WITH RADIO REMOTE CONTROL KAL-FIRE’s FERA range is a product that will bring you years of 3.3.1 IGHTING THE BURNERS pleasure. We advise you to check the appliance on delivery for 3.3.2...
  • Page 3: Installation Instructions

    Installation instructions Flue requirements. With the Fera you have a choice of two types of wall duct (C11) or two types of roof duct (C31). It is important to choose the right wall/roof Please take note of the following instructions before connecting the duct for the right situation.
  • Page 4: Example Of Duct

    Fires in the FERA range can only be connected with KAL-FIRE Example of duct concentric RVS flue gas material, otherwise no warranty can be given for the system. This is because during CE testing the appliances are 1.2.1 wallduct certified with this duct, and different resistance values apply to each duct.
  • Page 5: Roofduct For Existing Flue

    Roofflashing 20°-45° fumes. KF2CLS1004560 At the bottom of the chimney you have to Roofflashing 45°-60° use an other connector ( ) to KF2CSAFPL1050 create a good fit with the Kal-Fire concentric flue. KF2CBO1000045 KF2CSC100300 Adjustable pipe KF2CVO100 Ceiling support •...
  • Page 6: Restrictor Plate

    The MAXIMUM vertical system length must be less than 12 m (< 12 Restrictor plate m!). If it is desirable to mount part of the flue horizontally, the 12- metre vertical system length can be converted to the horizontal. In some installation chimney draught may be stronger than strictly Horizontal elements create considerable resistance, which is 1.5 times necessary.
  • Page 7: Technical Data

    Technical data 1.5.4 Fera 105 Model BE/FR AT/CH/GB/IT Propane 1.5.1 Fera 60 Type C11 / C31 C11 / C31 C11 / C31 C11 / C31 C11 / C31 Gas / P G20 / 20 mbar G20 / 20 mbar Model BE/FR AT/CH/GB/IT Propane...
  • Page 8: Building-In Instructions

    The concentric flue has already been covered in detail in appliance with radio remote control. The better the cooling, the longer Chapter 1 and should be manufactured by Kal-Fire. the life of the fire. All appliances are tested and inspected with the Uni which does not have convection grates and the standard one which does have convection grates.
  • Page 9: Positioning Of The Chips/Moulded Fire Bricks/ White Stones And Logs

    2.2.2 Positioning of the chips/moulded fire bricks/ white Tip 1: Cutting through the chips will produce a thinner chip which will stones and logs glow more. Tip 2: Before putting the chips in place, it is best to position the Caution ! rearmost log first, and also the two logs on either side.
  • Page 10 For the Fera 60: For the Fera 75: This is the set of logs you have received: This is the set of logs you have received: Figuur 5: Houtstammetjes Fera 60 The set of logs is to be positioned as follows. The set of logs is to be positioned as follows.
  • Page 11 For the Fera 75-corner: For the Fera 105: This is the set of logs you have received: This is the set of logs you have received: The set of logs is to be positioned as follows. The set of logs is to be positioned as follows. Figure 7: Fera 75-corner logs Figure 8: Fera 105 logs...
  • Page 12: Mounting Of The Convection Set For The Fera

    2.2.3 Mounting of the convection set for the Fera To do so, break off the convection covers on top of the appliance and Irrespective of the size of the Fera fire, the convection sets (Figure 9) screw on the connection mouths supplied. Connect as described consist of 1 or 2 flexible aluminium pipes, 4 or 8 clamping bands, 2 below.
  • Page 13: Assembling The Design Mantle

    Mind that the front (glass plate) of the fire appliance is level to the front of the 6. Connect the flue gas line using the Kal-Fire concentric mantle. stainless steel flue pipes.
  • Page 14: Stove

    Fera 60 stove The mantle and main frame are fully checked at our factory for possible damages prior to their packing. Nevertheless, please verify the appliance for possible transport damage before installing it. Contents of the Fera 60 stove consist of: •...
  • Page 15: Moulded Fire Clay

    0.38 kg / dm³. 2.6.1 Mounting of the fire clay The mounting of the fire clay is not included in this manual. Kal-fire runs courses on this. Figure 11: Manually controlled appliance Once the pilot light is lit, it heats up a thermocouple which creates a small flow.
  • Page 16: Extinguishing The Burners

    Now release the knob (1). If the pilot light does not keep burning, Appliances with ultrasound remote control wait for 3 minutes and then repeat the above steps. 3.2.1 Lighting the burners Now turn the knob (1) fully in the opposite direction, as far as the Make sure the gas tap is turned on.
  • Page 17: Appliances With Radio Remote Control

    Appliances with radio remote control Now turn the knob (3) fully in the opposite direction, as far as the position with the “big flame”. You can now adjust the height of the Take the battery-protection strip out of the manual transmitter and flames with check that the battery is still correctly positioned between the two...
  • Page 18: Dimensions

    If the automatic burner unit (Figure 16) is accessible, this can be Dimensions reset by pressing in a reset knob (3). You can see that this is locked by the red lamp (3). After the reset cycle, lasting about 10 seconds, you can re-start by simultaneously pressing the ON and OFF knob.
  • Page 22 Fera 75 corner RIGHT...
  • Page 23 Fera 75 corner LEFT...
  • Page 24: Troubleshooting

    The Fura burns very blue. Check the flue (It needs ±30 minutes in connection: does this comply Contact your dealer. order to heat up with Kal-Fire’s installation conditions? completely.) Please contact your dealer about other problems.
  • Page 25: Solutions Flowchart - Fera Ultrasound

    The Fura burns very blue. Check the flue connection; reacts well. and receiver are charged. (It needs ±30 minutes in does this comply with Kal-Fire’s Contact your dealer. YesJa order to heat up completely) installation conditions? The Fura burns very blue.
  • Page 26: Warranty Certificate

    Customer :_________________________ appliance. The warranty period for Kal-Fire gas appliances is 1 year starting on the date of Street :_________________________ purchase which must be clearly and distinctly stated on the sales invoice. The...
  • Page 27: The Warranty Is Not Applicable In The Following Cases

    The warranty is not applicable in the following cases: For appliances with remote control: when the electronics are not installed outside the fire and its radiation range, and are not installed to be fully insulated. If the above requirements are not, or are only partially, satisfied. If, without our knowledge, any modifications whatsoever are made to the appliances.