3-4. Installation

Where to install. The power inverter should be installed in a location that
meets the following requirements:
3-4-1. Dry - Do not allow water to drip or splash on the inverter.
3-4-2. Cool - Ambient air temperature should be between 0˚C
3-4-3. Safe - Do not install in a battery compartment or other areas where
flammable fumes may exist, such as fuel storage areas or engine
compartments.
3-4-4. Ventilated - Allow at least three inch of clearance around the inverter
for air flow.
the unit are not obstructed.
3-4-5. Dust-free - Do not install the Inverter in a dusty environments where
are dust, wood particles or other filings/shavings.
These dust can be pulled into the unit when the cooling fan is
operating.
3-4-6. Close to batteries - Avoid excessive cable lengths but do not install
the Inverter in the same compartment as batteries.
Use the recommended wire lengths and sizes (see section 2-10).
Also do not mount the Inverter where it will be exposed to the gases
produced by the battery.
These gases are very corrosive and prolonged exposure will damage
the Inverter.
Ensure the ventilation openings on the rear and front of
WARNING!
You may observe a spark when you make this
connection since current may flow to charge
capacitors in the power inverter.
Do not make this connection in the presence of
Flammable fumes.
Explosion or fire may result.