Programming Auto Disconnect Time Settings; Periodic Diagnosis Time Interval Settings - Panasonic KX-TDA5480 Programming Manual

4-channel voip gateway card
Hide thumbs Also See for KX-TDA5480:
Table of Contents

Advertisement

Parameter & Description
Password
Administrator-level log-in password.
Password (Confirmation)
Confirmation of the administrator-level log-in
password.

Programming Auto Disconnect Time Settings

Parameter & Description
Programming Auto Disconnect Time (min) 1-
30min
Specifies the time (in minutes) until programming is
automatically terminated.
If the specified period of time passes with no
programming input, programming will automatically be
terminated. This prevents problems caused by
continuation of log-in status in cases such as being
unable to log out due to the sudden failure of a PC.

Periodic Diagnosis Time Interval Settings

Parameter & Description
*
Periodic Diagnosis Time Interval (min) 0-
1440min
Specifies the time (in minutes) between periodic self-
diagnoses to test operation as described in "2.3.3
Diagnosis".
If failures are detected during the self-diagnosis, the
card will alert the PBX.
Program Version
Parameter
Program Version
Default
Value Range
Administrator
Max. 16 characters
No default
Max. 16 characters
Default
Value Range
10
1 to 30
Default
Value Range
60
0 (no periodic
diagnosis),
1 to 1440
Default
Value Range
Display only
Programming Guide
2.3 Maintenance
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda 0484

Table of Contents