Heating System; Electricity Connections - Jaspi TRIPLEX Installation And User Manual

Multifuel boilers
Table of Contents

Advertisement

Heating system

Central heating mixing valve
The boiler's standard equipment includes a 4-way mixing valve which is connected to the
flange on top of the boiler.
The pipe entering the radiator network is connected to the left (seen from the front) and the
return pipe to the right side of the valve.
The temperature of the outflow water that is needed in the network varies considerably. Thus
we recommend adding a motorised controller to the valve.
Circulating water pump
The best location for the circulating water pump is the radiator network flow pipe. To ensure
the pump's good functioning, removal of the accumulated air from the network should be taken
care of.
Energy accumulator (Thermal storage tank)
The boiler should be connected to an energy accumulator (with volume 250-1500 litres) if
firewood burning is frequent. A reliable loading valve (e.g. Termovar) should be used in the
coupling which ensures that the returning water temperature does not fall below 60 ° C.
Electricity connection
The boiler's electricity connections must only be performed by a qualified electrician.
The connections are made according to the following scheme.
FEED FROM BURNER SWITC
MAX.240V/10A
N L1 1 2 3
IMIT 2
TG 1
S1
c
BURNER
CUT-OFF
THERMOSTAT
FEED 230-240V 1~ FROM MAINSWITCH OF HEATING ELEMENT
***6kW 30A 3x10mm°
* 2kW 10A 3x1,5mm°
BURNER
6mm°
X1
4mm°
Signal lamp
1
S2
c
BURNER
THERMOSTAT
**4kW 20A 3x6mm°
N L1
*
*
*
11/R
21/S
31/T
2,5mm°
H
12/U
22/V
32/W
6mm°
HEATING ELEMENT
(SPL 3x2kW 230V)
WWW.JASPI.UK
4
X2
10mm°
CUT-OFF
THERMOSTAT
S3
THERMOSTAT