10.3.5 Piping Insulation

1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation
Diagram. Please wrap the insulated piping end to prevent water from going inside the piping.
2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by
using POLY-E FOAM with thickness 6 mm or above.
Note:
Enabling long-range remote control
To maintain EMC emission limits, cabling interconnecting the HA terminal and subsequent opto-coupler isolation,
must be no more than 1.9 m in length.
Loop four turns of this cable through a suitable small EMC ferrite toroid, and protect with a short length of large
diameter heat-shrink tube.
There is no similar length limit for cable following on from the opto-coupler isolation.