Indoor Unit - Panasonic CS-S9PKR Service Manual

Hide thumbs Also See for CS-S9PKR:
Table of Contents

Advertisement

10.2 Indoor Unit

10.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent if from vibration.
S9***, S12***
S18***, S24***,
S28***
The center of installation plate should be at more than
The distance from installation plate edge to ceiling should more than
From installation plate left edge to unit's left side is
From installation plate right edge to unit's right is
B
: For left side piping, piping connection for liquid should be about
: For left side piping, piping connection for gas should be about
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2
Drill the piping plate hole with ø70mm hole-core drill.
Line according to the left and right side of the installation plate. The meeting point of the extended line is
o
the center of the hole. Another method is by putting measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively.
Drill the piping hole at either the right or left and the hole should be slightly slanting to the outdoor side.
o
10.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the busing to the sleeve.
3
Cut the sleeve until it extrudes about 15 mm
from the wall.
4
Finish by sealing the sleeve with putty or
caulking compound at the final stage.
Model
1
490 mm
590 mm
3 .
4 .
Dimension
2
3
82 mm
439 mm
432 mm
82 mm
539 mm
532 mm
1 at right and left of the wall.
2 .
5 from this line.
6 from this line.
38
4
5
6
43 mm
95 mm
169 mm
219 mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents