Cleaning And Maintenance; Technical Specifications - DGM Kameleon 36X3W User Manual

Led par 64 rgb
Table of Contents

Advertisement

CLEANING AND MAINTENANCE

Di sc on nect fro m mains b efo re star tin g ma inten an c e o pera tio n !
The operator has to make sure that safety-relating and machine-technical installation are inspected
by
- an expert after every four years in the course of an acceptance test.
- a skilled person once a year.
1. All screws used for installing the devices or parts have to be tightly connected and must not be
corroded.
2. There must not be any deformations on the housing, fixations and installation spots (ceiling,
suspension, trussing, etc.)
3. The electric power supply cables must not show any damages, material fatigue (e.g. porous
cables) or sediments. Furthur instructions depending on the installation spot and usage have to be
adhered by a skilled installer and any safety problems have to be removed.
The interior of the device need to be cleaned at least annually by an air-jet or a vacuum cleaner.
There are no serviceable parts inside the device except for the lamp and fuse. Maintenance and
service operation can be only carried by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact DGM.

TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
LED quantity:
Service life:
Working mode:
DGM Lighting products
AC 200-250V, 50Hz ~
110W
36x3W RGB-in-1 LEDs (red 1w + green 1w + blue 1w)
Exceed 50,000 hours
Sound-activated via built-in microphone
Auto programs / Manuel setting
DMX 512 control, 8 channels
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents